Panasonic EX-Z Series User Manual page 8

Ultra-minute photoelectric sensor
Table of Contents

Advertisement

EX-Z12□, EX-Z12F□
<Parallel deviation diagram (typical)>
200
100
0
100
50
Left
Center
Operation distance ℓ(mm)
<Installation interval>
EX-Z13□, EX-Z13F□
<Parallel deviation diagram (typical)>
800
600
400
200
0
100
50
Left
Center
Operation distance ℓ(mm)
<Installation interval>
8
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
(L2)
(ℓ2)
0
50
100
Right
200mm
(L3)
(ℓ3)
0
50
100
Right
500mm
In case using at sensing distance (L2) 200mm, the
operation point (ℓ2) is approx. 30.5mm according
to the diagram at left.
The installation interval is
Approx. 30.5mm X 2 = approx. 61mm
Thus, install the product to approx. 61mm or more
away.
61mm
61mm
In case using at sensing distance (L3) 500mm, the
operation point (ℓ3) is approx. 81.9mm according
to the diagram at left.
The installation interval is
Approx. 81.9mm X 2 = approx. 163.8mm
Thus, install the product to approx. 163.8mm or
more away.
163.8mm
163.8mm