Download Print this page

Omega Engineering TX801R User Manual

Tx801r series programmable isolating resistance transmitter

Advertisement

Quick Links

Where Do I .ind Everything I Need for
Process Measurement and Control?
OMEGA...Of Course!
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND .ORCE
Transducers & Strain Gauges
Load Cells & Pressure Gauges
Displacement Transducers
Instrumentation & Accessories
.LOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine / Paddlesheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
Recorders, Printers & Plotters
HEATERS
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
M3470/0302
User's Guide
An OMEGA Technologies Company
http://www.omega.com
e-mail: info@omega.com
TX801R SERIES
PROGRAMMABLE ISOLATING
RESISTANCE TRANSMITTER

Advertisement

loading

Summary of Contents for Omega Engineering TX801R

  • Page 1 Immersion & Band Heaters Flexible Heaters Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL Metering & Control Instrumentation Refractometers Pumps & Tubing TX801R SERIES Air, Soil & Water Monitors Industrial Water & Wastewater Treatment PROGRAMMABLE ISOLATING pH, Conductivity & Dissolved Oxygen Instruments RESISTANCE TRANSMITTER M3470/0302...
  • Page 2 Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of contains, and reserves the right to alter specifications without notice.
  • Page 3 (usually less than 1%). To remove this error take a low (approx 10%) and a high (approx 90%) reading -Low Voltage (L) 8~30Vac and 8~30Vdc; 50/60Hz; 4VA. of the variable being measured by the transducer supplying the signal to the TX801R, and ensure that this agrees with -Circuit Sensitivity <±0.001%/V FSO Typical.
  • Page 4 TX801R Output Range Programming Table. TX801R Input Programming. Notes: 1/ Switch status 1 = ON 0 = OFF. Always set OUTPUT range first, then INPUT range. Output ranges with '*' beside them reverse the polarity of the output connections. If the input range is not listed in the programming table, use the following formulae to work out the Zero and Span DIP switch settings for gain.