Download Print this page

Honeywell Prestige THX9000 System Installation Manual page 13

Hide thumbs Also See for Prestige THX9000:

Advertisement

Available languages

Available languages

Installer setup tables
Setup functions
393
Away mode high temp. setting
394
Away mode dehumidification
400
Ventilation Control
401
Number of Bedrooms
402
Total Sq. Ft. of Home
403
Ventilation CFM
404
Max Ventilation Percentage Limit
405
Ventilation Fan Action
406
Ventilation in High Humidity
431
Ventilation Lockout High Temperature
432
Ventilation Lockout Low Temperature
500
Reminder: Furnace filter
502
Furnace filter runtime counter
510
Reminder: Humidifier pad
520
Reminder: UV bulb
525
Installer Custom Reminders
530
Adaptive Intelligent Recovery
540
Number of schedule periods
580
Minimum compressor off time
600
Maximum heat range
610
Minimum cool range
640
Clock format
650
Extended fan on time (heat)
660
Extended fan on time (cool)
670
Keypad lock
680
Temp. control (heat)
690
Temp. control (cool)
700
Temperature display offset
701
Humidity display offset
710
RESTORE FACTORY DEFAULTS
Customer contact information
1100
Dealer name
1150
Dealer phone number
1200
Dealer email address
1250
Dealer website
1300
Dealer Message
1400
Configurable U1 Relay
1405
Configurable U2 Relay
1500
Low Speed Fan Position
Note: All installer options, including Dealer name, contact information and message can be
set up as a file and downloaded via the USB port on the thermostat.
(factory default setting listed, other options available)
(optional, but recommended)
13
85° F (29.5° C)
65% relative humidity
Off
2
1000
160
50%
Ventilation Forces Fan On
On
None
None
Off
Count heat and cool
Off
Off
Add Customer Reminder
On
4
5 minutes
90° F (32° C)
60° F (15.5° C)
12-hour
Off
Off
Unlocked
Standard
Standard
No offset
No offset
No: Advanced Options
Your company name
Your telephone contact
Your email address
Your web site
Edit
None
None
Normally Closed
69-2057EFS—03

Advertisement