For Wall Mounted Type < ASU18RLF >
1. VERTICAL LOUVER CONTROL
(Function Range)
Each time the button is pressed, the air direction range will change as follow:
Types of Air flow Direction Setting:
: During Cooling / Dry / Heating / Fan modes
①,②,③,④,⑤,⑥
Use the air direction adjustments within the ranges shown above.
The vertical airflow direction is set automatically as shown,
in accordance with the type of operation selected.
Cooling / Dry mode : Horizontal flow ①
Heating mode
When the temperature of the air being blown out is low at the start of heating operation or during
defrosting, the airflow direction temporarily becomes ① to prevent cold air being blown onto the body.
During use of the Cooling and Dry modes, do not set the Air Flow Direction Louver in the Heating
range ( ④~⑥ ) for long period of time, since water vapor many condense near the outlet louvers and
drop of water may drip from the air conditioner. During the Cooling and Dry modes, if the Air Flow
Direction Louvers are left in the heating range for around
2. HORIZONTAL LOUVER CONTROL
(Function Range)
Each time the button is pressed, the air directionrange will change as follows.
Cooling / Heating / Dry mode / Fan mode
3. SWING OPERATION
Vertical Airflow Swing Operation
When the swing signal is received from the remote controller,
the vertical louver starts to swing.
(Swinging Range)
Cooling mode / Dry mode / Fan mode( ①~③ : )
Heating mode / Fan mode( ④~⑥ )
When the indoor fan is S-Lo or Stop mode, the swing operation is interrupted
and it stops at either upper end or bottom end.
Horizontal Airflow Swing Operation
When the swing signal is received from the remote controller, the horizontal louver starts to swing.
(Swinging Range)
All mode :
When the indoor fan is S-Lo or Stop mode, the swing operation is interrupted
and it stops at either upper end or bottom end.
Vertical and Horizontal Airflow Swing Operation
When the horizontal swing signal is input from remote control, the combination of the vertical
and horizontal swing operation is performed.
Power Diffuser doesn't swing in any swing operation.
: Downward flow ⑤
Vertical Louver
20
minutes, they will automatically return to position ③.
:
01-11
( Fig. 7 : Vertical air direction range )
Power Diffuser
( Fig. 8 : Horizontal air direction range )
Horizontal Louver