7.8.5

the Statistics menu

Counting and evaluation of received frames
A SCALANCE X-204RNA has internal statistics counters with which it counts the number of
received frames for each port according to the following criteria:
● Frame length
● Message frame type
● Bad frames
This information provides you with an overview of the data traffic and any problems on the
network.
7.8.6

Packet Size Statistic

Received frames sorted by length
The "Packet Size Statistics" page displays how many packets of which size were received at
each port.
If you click the "Reset Counters" button, you reset the counters for all ports.