10 Adjustment Procedure

10.1. +B Set-up

10.1.1. Item / Preparation
1. Input a Grey scale signal.
2. Set the picture controls: -
Picture mode: Normal
White balance: Normal
10.1.2. Adjustments
Adjust and confirm indicated test point for the specified voltage.
Adjust
Name
Test point
PFC
P24 pin 1
Vsus
P1 pin 2
Vda
P3 pin 1
Confirm
Name
Test point
+18V
P4 pin 1
+13.5V
P5 pin 1
Audio +15V
P6 pin 1
Audio -15V
P6 pin 3
5.25V
P5 pin 5
STB5V
P7 pin4
Voltage
Volume
400V ±1V
R548
175V ±1V
R639
75.0V ±0.5V
R545
Voltage
17.2V ±0.5V
13.2V ±0.5V
13.5V ±0.5V
-13.5V ±0.5V
5.1V ±0.3V
5.0V ±0.3V

10.2. Driver Set-up

10.2.1. Item / Preparation
1. Input an APL 100 % white signal.
2. Set the picture controls: -
Picture mode: Normal
White balance: Cool
Aspect: 16:9
10.2.2. Adjustments
Adjust driver section voltages referring the panel data on the
panel data label.
Name
Test point
Vsus
TPVSUS
(SS-BOARD)
Vbk
TPVBK
(SC-BOARD)
Ve
TPVE
(SS-BOARD)
Vset
TPVSET
(SC-BOARD)
Vad
TPVAD
(SC-BOARD)
Vda
TP117
(C9-BOARD)
Vscn
TPVSCN
(SC-BOARD)
*See the Panel label.
13
PDM-1U / G / R /
Voltage
Volume
Vsus ±1V*
R639
(P3-BOARD)
Vbk ±5V*
R6670
(SC-BOARD)
Ve ±1V*
R6770
(SS-BOARD)
218 V ±6V
---
Vad ±1V*
R6477
(SC-BOARD)
74V±1V
R545
(P1-BOARD)
Vad+118±2V
---