T101-2293-1,03,02 GX4000 R3.0 Series E band Impulse Radio System User Guide T101-2293-01 Issue 1.03.02 2014 July FUJITSU LIMITED...
Page 2
Fujitsu’s further design improvements. Non-Disclosure Fujitsu Limited has taken every care that the contents of this document are correct at the time of going to press. If any errors are found, or any other comments are wished to be made, Please do not hesitate to contact us.
Contents 1. System Description Overview ………………………………………………………… 1-1 System Overview ………………………………………………. 1-1 Ordering Information …………………………………………… 1-4 General Specification ………………………………………….. 1-14 Environmental Specification ………………………………….. 1-24 Power requirement …………………………………………….. 1-29 Reference Data(Throughput) ………………………………….. 1-34 2. Installation & Site Survey Overview ………………………………………………………… 2-1 Installation & Site Survey Guideline ………………………….. 2-1 Unpacking ………………………………………………………..
Page 4
5. Web-Based Local Terminal (WebLT) WebLT …………………………………………………………….. 5-1 Getting Started with WebLT ……………………………………. 5-2 Menu Tree for Ethernet Interface ………………………………. 5-8 Menu Tree for CPRI Interface ………………………………….. 5-10 WebLT Menu and Description …………………………………. 5-13 Summary ………………………………………………………….. 5-15 Configuration > Alarm …………………………………………….5-17 Configuration >...
Page 6
CAUTION: A CAUTION indicates a potential for property damage, personal injury or death. Important Observe all warnings in the text and on equipment labels regarding high-voltage or high temperature conditions. The fallowing warnings and figures apply to most FUJITSU product.
Page 8
The contents of this document are subject to change without notice since Fujitsu Limited reserves the right to make changes in equipment design or components or firmware release roadmap without notice, as progress in engineering or manufacturing methods may warrant. Neither this document nor any portion thereof, is to be reproduced in any form whatsoever without written permission from Fujitsu Limited.
Power requirement System Overview Two Types of Signal Interface Fujitsu BroadOne GX4000 series E-band impulse radio is complete All-In-One ODU radio employing impulse modulation technology. Two (2) types of signal interfaces are available, one is Ethernet interface (10GbE and/or 1GbE) and the other is CPRI (Common Public Radio Interface) (*1) interface for mobile communication.
Page 11
Fujitsu and Fujitsu Customer Use Only System Description Features & Performance Wireless Innovation based on Impulse Radio 70/80 GHz E-Band 1+0 point-to-point radio Lightweight, small size zero-footprint ODU design < 3.0 litter and < 3.0 kg ...
System Description Fujitsu and Fujitsu Customer Use Only Ordering Information Ordering Guide < Configuration Tree of GX4000 System per Link > GX4000 System Ether interface, DC 70G GX4000 for Ether for station A (B): x 1 70G Ether DC Signal interface: 10GBASE-LR & 1000BASE-T...
Page 13
Fujitsu and Fujitsu Customer Use Only System Description GX4000 System Ether interface, AC 70G E-band IR for Ether for station A (B): x 1 70G Ether AC Signal interface: 10GBASE-LR & 1000BASE-T 80G E-band IR for Ether for station B (A): x 1 80G Ether AC Signal interface: 10GBASE-LR &...
Page 14
System Description Fujitsu and Fujitsu Customer Use Only GX4000 System CPRI interface, DC 70G E-band IR for CPRI BBU for station A (B): x 1 70G CPRI BBU User rate: 2,4576 Mbit/s 80G E-band IR for CPRI RRH for station B (A): x 1...
Page 15
Fujitsu and Fujitsu Customer Use Only System Description GX4000 System CPRI interface, AC 70G E-band IR for CPRI BBU for station A (B): x 1 70G CPRI BBU User rate: 2,4576 Mbit/s 80G E-band IR for CPRI RRH for station B (A): x 1...
Page 16
System Description Fujitsu and Fujitsu Customer Use Only Mechanical Configuration To introduce the GX4000 system, it is necessary to select equipment, proper materials and cables regarding to the Application Code. Table 2.1 shows the code. Mounting Pole GX4000 Cassegrain antenna...
Page 17
Fujitsu and Fujitsu Customer Use Only System Description Ordering Code Table 2.1a Code for GX4000 Equipment Description Ordering Code TX=70 GHz & RX=80 GHz band GX4000 Ether 70G DC Ethernet interface, 3.0 Gbps, GX4380LE3D 2-SMF, DC -48 V TX=80 GHz & RX=70 GHz band GX4000 Ether 80G DC Ethernet interface, 3.0 Gbps...
Page 18
System Description Fujitsu and Fujitsu Customer Use Only Table 2.1b Code for Antenna Description Ordering Code 1-feet antenna Cassegrain Antenna, 1-feet Direct connection to GX4000 GX4K80ATP11 Including mounting kit 1-feet antenna Cassegrain Antenna, 2-feet Direct connection to GX4000 GX4K80ATP12 Including mounting kit Table 2.1c Code for DC Power Cable...
Page 19
Fujitsu and Fujitsu Customer Use Only System Description Table 2.1e Code for Ether Electrical Cable Description Ordering Code Ether electrical cable, 1 m Ether cable, 1 m GX4K80CBET01 Ether electrical cable, 5 m Ether cable, 5 m GX4K80CBET05 Ether electrical cable, 10 m...
Page 20
System Description Fujitsu and Fujitsu Customer Use Only Table 2.1h Code for CPRI 1-SMF Optical Cable Description Ordering Code CPRI optical cable,1 m CPRI, 1-SMF, single mode, 1 m GX4K80CB1S01 CPRI optical cable,5 m CPRI, 1-SMF, single mode, 5 m...
Page 21
Fujitsu and Fujitsu Customer Use Only System Description Table 2.1j Code for DC Power Connector Description Ordering Code DC power connector 4P connector GX4K80CNPD Table 2.1k Code for AC Power Connector Description Ordering Code AC power connector 3P connector GX4K80CNPA Table 2.1l Code for IO Connector...
System Description Fujitsu and Fujitsu Customer Use Only General Specifications System Specification Table 1.4-1 System Specification Item Description 70/80 GHz band (E-Band) RF Band Used in accordance with ETSI EN302 217-3 V1.3.1 (2009-07) Annex UC 70 GHz band: 71,0 to 76.0 MHz 80 GHz band: 81,0 to 86.0 MHz...
Page 23
Fujitsu and Fujitsu Customer Use Only System Description Transmitter Side Specification Table 1.4-2 Transmitter Part Item Description RF Output Power 0 to +10 dBm measured at antenna port RF output power tolerance: -3.0 / +0.8 dB RF Output Power < -40 dBm...
Page 24
System Description Fujitsu and Fujitsu Customer Use Only RX MON RX MON Figure 1.4-1 Schematic Block Diagram of GX4000 TX Output Power Density Mask 0%/-15 20%/-15 50%/-25 50%/-30 57.5%/-45 70%/-45 125%/-65 100% 150% 200% 250% Frequency Offset from Center of Frequency relative to aggregated channel Figure 1.4-2a Output Power Density Mask...
Page 25
Fujitsu and Fujitsu Customer Use Only System Description Frequency (GHz) Figure 1.4-2b Unwanted Emission Power Density at the Antenna port (In accordance with ETSI EN 302 217-3 V1.3.1 (2009-07) Annex UC Aggregation Channel (CS=4.5 GHz) GX4000 Power Density スペクトラムマス Mask ク...
Page 26
System Description Fujitsu and Fujitsu Customer Use Only Receiver Side Specification Table 1.4-3 Receiver Part Item Description Noise Figure 11.5 dB typical 12 dB guaranteed Noise figure is measured at Point C (antenna port) in accordance with ETSI EN302 217-1 (2007-06) & at maximum gain of RF AMP.
Page 27
Fujitsu and Fujitsu Customer Use Only System Description Transmit-Receive Overall Performance Table 1.4-5 BER Performance Overall Item Description BER = 10 –6 at RSL of –25 dBm typical Upfade BER BER = 10 –6 at RSL of –28 dBm guaranteed measured at antenna RF input port BER = 10 –6 at RSL of –54 dBm typical...
Page 28
System Description Fujitsu and Fujitsu Customer Use Only Ethernet 1GbE Electrical Interface Table 1.4-7 1000BASE-T Electrical Interface Specification IEEE802.3-2008 (10/100/1000BASE-T) Connector RJ-45 Channel Transfer speed 10 Mbit/s, 100 Mbit/s, 1,000 Mbit/s Transmission capacity 10 Mbit/s, 100 Mbit/s, 1,000 Mbit/s Cable used...
Page 29
Fujitsu and Fujitsu Customer Use Only System Description CPRI MMF Interface Table 1.4-9 CPRI MMF Interface Specification CPRI specification V5.0 (2011-09-21), optical Connector LC duplex, 2xLC Channel Transmission speed 2,457.6 Mbit/s Transmission capacity 2.457.6 Mbit/s Optical Fiber used 850 nm multi-mode fiber...
Page 30
System Description Fujitsu and Fujitsu Customer Use Only Recommended L2SW Module Interface Table 1.4-12a Line Side Interface of L2SW Line Side Interface 1000BASE-LX, maximum x3 channels Connector LC duplex (LCx2) Transmission Speed 1.25 Gbit/s Transmission Capacity 1.25 Gbit/s 62.5 μm multi-mode fiber (MMF) Optical Fiber Used μm multi-mode fiber (MMF)
Page 31
Fujitsu and Fujitsu Customer Use Only System Description Cassegrain Antenna Table 1.4-11 Parabolic Antenna 1-feet antenna 2-feet antenna 71.0 to 76 GHz & 81.0 to 86.0 GHz Antenna Gain 43 dB (typical) 48 dB (typical) Half Beam Width 1.0 degree (typical) 0.6 degree (typical)
System Description Fujitsu and Fujitsu Customer Use Only Environmental Specification Environmental Condition Not In-Use Condition (Storage/Transportation) Table 1.5-1 shows the storage/Transportation conditions when E-band radio equipment and base band conversion module are not operational. (Not in-use condition). Table 1.5-1a Environmental Condition - Storage -...
Page 33
Fujitsu and Fujitsu Customer Use Only System Description In-Use Condition Table 1.5-2 shows the environmental conditions when GX4000 equipment is operational. (In-use condition). Table 1.5-2 Environmental Condition - In-Use condition - Item Description Out-door use Classification In accordance with ETSI EN 300 019-1-4 V2.1.2 (2003-04) Class 4.1: Non-weatherprotected locations and...
Page 34
System Description Fujitsu and Fujitsu Customer Use Only Electro-Magnetic Compatibility EMC requirements are in accordance with ETSI EN 301 489-1 V1.8.1 (2008-04) and ETSI EN 301 489-4 V1.4.1 (2009-05). Table 1.5-3 shows the EMC emission test method and limits Table 1.5-3 EMC Emission Test Method and Limits...
Page 35
Fujitsu and Fujitsu Customer Use Only System Description Immunity Table 1.5-6 shows the Immunity test methods and conditions. Table 1.5-6 Immunity Test Method and Conditions Phenomenon Application Requirement Enclosure a) Test method is in accordance with EN 61000-4-3 (2006) electromagnetic b) Test level is 3 V/m (measured unmodulated).
Page 36
1,040 >30 GX4000, 70/80G CPRI 1,040 >30 1/2-feet Antenna >30 Note-1: Actual MTBF value is estimated 3 to 5 times better than calculated one from the field data of Fujitsu digital microwave radio. 1-28 BroadOne GX4000 Manual (R3.0) issue 1.03...
Fujitsu and Fujitsu Customer Use Only System Description Power Requirements Power Supply Interface Requirement DC -48 V Power Feed Table 1.6-1 shows the power supply interface requirement in accordance with ETSI EN300 132-2 V2.2.2 (2007-10) below; Table 1.6-1 Power Supply Requirement at Interface “A”...
Page 38
System Description Fujitsu and Fujitsu Customer Use Only Table 1.6-1 Power Supply Requirement at Interface “A” (Cont’d) Item Specification The supply at interface “A” shall be protected by circuit breaker or other (5) Supply protection such devices. Circuit breaker is installed outside GX4000.
Page 39
Fujitsu and Fujitsu Customer Use Only System Description Immunity to narrow band Specification Emission of narrowband noise Specification AC 240 V Power Feed Table 1.6-2 shows the power supply interface requirement in accordance with ETSI ETS 132-1 (September 1996) below;...
Page 40
System Description Fujitsu and Fujitsu Customer Use Only (c) Abnormal service voltage under temporary conditions Abnormal service voltage under temporary conditions and surge testing simulating these temporary conditions are covered by ETS 300 386-1. (d) Recovery from steady state abnormal voltage Abnormal service voltage shall not lead to the disconnection of power supply units e.g.
Fujitsu and Fujitsu Customer Use Only System Description Power Consumption The power consumption of each unit is shown in Table 1.6-3. Table 1.6-3 Power Consumption of Each Equipment Unit Pc (W) Remarks GX4000 Ether 70G GX4000 Ether 80G GX4000 CPRI BBU 70G...
System Description Fujitsu and Fujitsu Customer Use Only Reference Data GX4000 Link Throughput The measurement result of GX4000 Link Throughput by RFC2544 standard is shown as follows. GX4000 R3.0 product / Max Test BW 3500 L1 Mbps / Indoor RF connection...
Page 43
Fujitsu and Fujitsu Customer Use Only System Description GX4000 R3.0 product / Max Test BW 3500 L1 Mbps / Indoor RF connection Layer 3 Traffic Term mode 1-35 BroadOne GX4000 Manual (R3.0) issue 1.03...
Fujitsu and Fujitsu Customer Use Only Installation Installation & Site Survey Overview This chapter describes how to install and do the site survey for BroadOne GX4000 E-band IR system. The main topics covered are; Installation & Site Survey Guideline ...
Page 45
Installation Fujitsu and Fujitsu Customer Use Only The first Fresnel zone is the area containing every point of which the distance from the transmitter to any reflection point on the area and on to the receiver is half a wavelength longer than the path of the direct signal.
Page 46
Fujitsu and Fujitsu Customer Use Only Installation Antenna Mounting Type The Site Survey Team will assess and report on any existing tower or antenna framework that may be usable. In the case of a rooftop location, a standard non–penetrating mounting with a 1.8 m antenna pole is standard.
Unpacking Verify that the item received are compliant with the packing list. If any part of the equipment is damaged, contact Fujitsu Limited representative for repair or replacement instruction. The ODU is packaged in two (2) separate boxes. In addition, the optional items such as cables are packaged in a separate container.
Page 48
Fujitsu and Fujitsu Customer Use Only Installation CAUTION: If there is an existing lightning rod, make sure that the ODU installation site is covered by the lightning protection cone. Misalignment under extreme weather conditions must not exceed ± 2 min.
Installation Fujitsu and Fujitsu Customer Use Only 2.4.2 Goods Necessary for Installation Table 2.4.2a Goods Necessary for Installation per Station Item Goods Code Quantity Remarks GX4000 GX4380 (*1)(*2)(*3) (*1): Radio frequency L: TX=70GHz/RX=80GHz U: TX=80 GHz/RX=70 GHz (*2): User interface...
Fujitsu and Fujitsu Customer Use Only Installation 2.4.5 Fixing Mounting Kit to Pole Step-1: Fixing Mounting Kit to Pole Loosely Mount fixing bolt Mount plate Holder Washer, spring washer & bolt Holder Mount fixing bolt 2-11 BroadOne GX4000 Manual (R3.0) issue 1.03...
Page 55
Installation Fujitsu and Fujitsu Customer Use Only Step-2: Adjust Fixing Mounting Kit Position Adjust mounting kit position to the direction of far-end station. Azimuth angle fixing bolts (x3) Rotate mount kit and adjust right direction to the far-end GX4000 station.
Page 56
Fujitsu and Fujitsu Customer Use Only Installation Step-4: Adjusting Elevation Bolt Position Loose the elevation bolt to the right position (see below). Take care for over loosing. Loosing elevation adjusting bolt to the right position Elevation adjusting bolt Step-5: Grease ...
Page 57
Installation Fujitsu and Fujitsu Customer Use Only Step-6: Installing Antenna Base to the Tilt Plate Install antenna base to the tilt plate through center pin. Antenna base hole Tilt plate pin Fit the antenna base hole to the centre pin of tilt plate Step-7: Fixing Antenna Base and Tilt Plate ...
Page 58
Fujitsu and Fujitsu Customer Use Only Installation Step-8: Set Antenna Vertical Angle to Zero Set antenna vertical angle to zero and install lock bolt.. Fix using elevation fixing bolts (x2) and lock bolt. Rated torque is 14.4 to 17.6 N/m.
Page 59
Installation Fujitsu and Fujitsu Customer Use Only Assembly of Connection Material with GX4000 Step-1: Polarization Setting Install connection material with GX4000 by 4xM5 bolts. Fix by 4 x M5 cross bolts. Rated torque is 4.9 to 5.9 N/m.
Fujitsu and Fujitsu Customer Use Only Installation Confirmation of Antenna Polarization Confirm antenna polarization. Default setting is V-Polarization. Polarization change procedure is as follows: (1) Loose M3 cross bolts (x2) on antenna feed part (2) Rotate antenna feed part by 90 degree.
Page 61
Installation Fujitsu and Fujitsu Customer Use Only Assembly of Antenna Base and GX4000 Set x4 3/8-inch UNC bolts depending on polarization. Fix by 4 x UNC bolts. Rated torque is 18 to 22 N/m. Interface Connector V-Polarized GX4000...
Fujitsu and Fujitsu Customer Use Only Installation Cable & Connector This section provides information on cable & connector of baseband, power supply & monitoring to/from the external communication equipment. 2.8.1 Cable and Connector Code Necessary for Installation Item Goods Code...
Installation Fujitsu and Fujitsu Customer Use Only 2.8.4 Pin Assignment of Connector Table 2.8.4a Pin Assignment of Connector (Optical Ether Cable) GX4000 Side Ext Equipment Side Item Signal Direction Connector Pin No. Label Connector SW20-LC Table 2.8.4b Pin Assignment of Connector (Optical CPRI 1-core Cable)
Page 66
Fujitsu and Fujitsu Customer Use Only Installation Table 2.8.4e Pin Assignment of Connector (AC Power Supply) GX4000 Side Ext Equipment Side Item Signal Direction Connector Pin No. Label Connector M4 crimp Water- M4 crimp Proof, G (*1) M4 crimp Round 4P...
Installation Fujitsu and Fujitsu Customer Use Only 2.10 Assembly of Connector 2.10.1 Optical Connector Purchasing of optical connector is not available. 2.10.2 Ether Connector Purchasing of Ethernet connector is not available. 2.10.3 I/O Connector I/O connector is waterproof round type 8P connector. Necessary components such as cable, criping terminal and marker tube are provided by the customer.
Page 72
Fujitsu and Fujitsu Customer Use Only Installation Step-2: Connector asembly > 3 mm Fit thermal tube after soldering Gasket Solder pot Thermal tube Soldering Clump tip Code Cup ring Clump - Rated fixing torque for cup ring and code can is 3N/m.
Page 73
Installation Fujitsu and Fujitsu Customer Use Only Step-5: Fixing FG to the Cable Skin the cable (10 mm) and FG cable is soldered to the shield mesh. Wrap the self-bonding insulating tape in the part of shield mesh.. Step-6: Fixing FG to the Connector One end of soldered shield mesh is wrapped to the connector CN1.
Page 74
Fujitsu and Fujitsu Customer Use Only Installation Step-7: Fitting thermal tube Put thermal tape covering connector CN1 and self-bonding insulating tape. Step-8: FG cable (CN2 side) One end of UL1007-AWG18 cable is skinned by 30 mm and soldered. Other end is skinned by 4.5 to 5 mm.
Page 75
Installation Fujitsu and Fujitsu Customer Use Only Wrap the self-bonding insulating tape on the part of shield mesh.. Step-10: Fitting to the TM5 Put the thermal tape (black) covering self-bonding insulating tape. Step-11: Fitting to the TM5 Crimping by tool...
Page 76
Fujitsu and Fujitsu Customer Use Only Installation 2.10.4 Power Supply Connector Power supply connector is waterproof, round type connector. Necessary components such as cable, criping terminal and marker tube are provided by the customer. Power Supply Connector Table 2.10.4a Necessary Component for DC Feed...
Page 77
Installation Fujitsu and Fujitsu Customer Use Only Accembling Procedure Step-1: Gasket assembly Gasket Array-A Step-2: Pre-assembly of CN1 Prior to connector assembly, crump, code can and thermal tube are through the cable. Step-3: Shield assembly of CN1 side cable Skin the cable shield by 10 mm and wrap cupper tape.
Page 78
Fujitsu and Fujitsu Customer Use Only Installation Step-4: Gasket Installation Install seven (7) gaskets around the cupper tape. Array-B Step-5: Gasket Fixing Put the thermal tape Thermal tube Step-6: Connection CN1 and cable After soldering to the solder bot, cover thermal tupe or silk tape to insulate.
Page 79
Installation Fujitsu and Fujitsu Customer Use Only Step-7: Fitting thermal tube & silk tape Fit the thermal tube between CN1 and cable. Thermal tube Wrap the silk tape to become φ11 Step-8: CN1 Assembly Ruber Tightning material Crump tip Crump...
Page 80
Fujitsu and Fujitsu Customer Use Only Installation Step-10: Fitting thermal tape to the CN1 Thermal tape Step-11: Crump of TM1 to TM3 Crumping by tool Crumping by tool Crumping terminal Crumping terminal M4 & 0.75 mm M4 & 1.5 mm Step-12: Frame ground (FG) One end of UL1007-AWG18 cable is skinned by 30 mm and soldered.
Page 81
Installation Fujitsu and Fujitsu Customer Use Only Step-13: Install FG cable to the cable Skin the cable (10 mm) and FG cable is wrapped & soldered to the shield mesh. Wrap self-bonding insulating tape to the shield mesh part. Step-14: Fit the thermal tape Put the thermal tape covering self-bonding insulating tape.
Fujitsu and Fujitsu Customer Use Only Commissioning Test Commissioning Test Overview This chapter explains the antenna orientation and how to do the commission test for the GX4000 link. Main topics covered are; Preparation Antenna alignment guideline Antenna alignment procedure ...
Commissioning Test Fujitsu and Fujitsu Customer Use Only Power Supply ON Remove PWR connector on ODU Set circuit breaker switch for ODU to ON. Confirm that DC power supply voltage on PWR connector; Voltage between Pin-1 (minus) and Pin-2 (plus)
Fujitsu and Fujitsu Customer Use Only Commissioning Test Antenna Alignment Guideline Introduction One of the most important elements of a wireless system deployment is the antenna system. Proper alignment of that antenna system is critical to the performance of any wireless system. Engineering a wireless link for the highest achievable system gain while minimizing or eliminating the potential for interference will help reach the goal of high availability.
Page 85
Commissioning Test Fujitsu and Fujitsu Customer Use Only Polarization Pre-Alignment Prior to raising the antenna to the tower or rooftop mounting position, the antenna polarization and ODU setting position should be verified and adjusted to correspond to Chapter 2, Section 2.5 Antenna Mounting.
Page 86
Fujitsu and Fujitsu Customer Use Only Commissioning Test 3.3V 3.0V 2.0V 1.0V -55 dBm -45 dBm -35 dBm -25 dBm Figure 3.5 Typical RSL Chart Once the antenna is set at peak level, tighten all adjustments and mounting hardware. Continue to monitor the RSL while doing this to ensure final tightening of the hardware has little to no effect on RSL.
Commissioning Test Fujitsu and Fujitsu Customer Use Only Antenna Alignment Procedure Step-1: Connecting WebLT to ODU RJ-45 Jack Connect PC with ETH connector (RJ-45 jack) on ODU by LAN cable. Open WebLT For detailed connection, refer to Chapter 5, Section 5.1.
Page 88
Fujitsu and Fujitsu Customer Use Only Commissioning Test Step-3: Time Data Setting Click Configuration > System > NTP Input Year/Month/Day/Hour/Minute/Second and click to set. Step-4: Radio Parameter Setting Click Configuration > Radio Set Target Tx Power (dBm) to 10.0 and click to save.
Page 89
Commissioning Test Fujitsu and Fujitsu Customer Use Only Step-5: Tx Output Power ON Click Test & Diagnostic > Control Click Release button and Tx-OFF turned to Tx-ON. TX output power is transmitted. Step-6: Monitoring RSL on MON Connector ...
Page 90
Fujitsu and Fujitsu Customer Use Only Commissioning Test Antenna Adjustment in the Vertical Direction Loose elevation fixing bolts (x2) Adjust elevation angle by using elevation adjustment bolt. Fix using elevation fixing bolts after catching peak RSL. Azimuth Adjustment...
Page 91
Commissioning Test Fujitsu and Fujitsu Customer Use Only Antenna Adjustment in the Holizontal Direction Loose azimuth fixing bolts (x6) Adjust azimuth angle by using azimuth adjustment bolt. Fix using elevation fixing bolts after catching peak RSL. Azimuth...
Page 92
Fujitsu and Fujitsu Customer Use Only Commissioning Test Continuity Test after Antenna Alignment After antenna alignment, continuity test is carried out Alarm Summary Indication Start WebLT and click Summary menu Check Alarm Summary and if Error, Warning and Info indication are issued, click Default Information button to indicate alarm description.
Page 93
Commissioning Test Fujitsu and Fujitsu Customer Use Only Table 3.7 Alarm and Severity of Alarm Summary Category Cause Factor Status Description Level EQPT Processor Failure EQPT Start-up Failure EQPT Internal Heath Check Failure EQPT Internal Clock Failure EQPT PLL Failure...
Page 94
Fujitsu and Fujitsu Customer Use Only Commissioning Test Table 3.7 Alarm and Severity of Alarm Summary (Cont’d) Category Cause Factor Status Description Level External Clock Degrade on Sync Ethernet Radio Radio Overhead Parity Error RF XAUI Packet Discard RF XAUI FCS Error...
Page 95
Commissioning Test Fujitsu and Fujitsu Customer Use Only Confirmation of RSL Click Monitor > Radio Performance > Current Radio Performance Current Confirm Current value. Item Parameter Specification Tx Level (dBm) TX output power Setting value +/- 3 dB...
Fujitsu and Fujitsu Customer Use Only Commissioning Test Parameter Item Specification (15min interval) Tx Level (dBm) Min. TX power (Min.) Setting value +/- 3 dB Max. TX power (Max.) Setting value +/- 3 dB Rx Level (dBm) Min. RSL (Min.) System design value +/- 3 dB Max.
Commissioning Test Fujitsu and Fujitsu Customer Use Only And also applicable/not applicable Monitor/Test & Diagnostics/ Maintenance menu items are listed below; GX4000 GX4000 Menu Tree Item Ether CPRI Minitor > Alarm Monitor > System Monitor > Ports Monitor > Security Monitor >...
Page 98
Fujitsu and Fujitsu Customer Use Only Commissioning Test Optional Telescope 3.9.1 Fixing Material (GX4K80ADMK) Two types for 1-feet and 2-feet casegrain antennas available Open sight (V-gap) and peep sight (round hole) for sighting device use Round hole for peep sight...
Page 99
Commissioning Test Fujitsu and Fujitsu Customer Use Only 3.9.3 Installation of Telescope NOTICE DO NOT LOOK directly at the sun, car headlight or bright lighting equipment. It may adversely affect eyes. NOTE Do not use under rain, under water and the place with much dust.
Page 100
Fujitsu and Fujitsu Customer Use Only Commissioning Test STEP-3: Installing Telescope on Mount Ring Put telescope on the mount ring parallet to the mount rail. Look in the telescope and set the telescope to adjust reticle Put the telescope on the mount ring.