Honeywell Lyric LCP500-LC Installation And Reference Manual page 21

Hide thumbs Also See for Lyric LCP500-LC:
Table of Contents

Advertisement

Type
Type
Type
Type
Can be assigned to any wireless zone used
Fire with
as a fire zone. Fire with verification is
Verification
available with smoke detector device type. It
cannot
combination heat/smoke detectors or fire
pull stations. This zone type is always active
and cannot be bypassed.
Special-purpose zone type used with 5800
Arm–Stay
and
SiX
Special-purpose zone type used with 5800
Arm–Away
and SiX Series wireless keys.
Special-purpose zone type used with 5800
Disarm
and SiX Series wireless keys.
Assigned when no-alarm response is required. •
No Alarm
Response
Can be assigned to any wireless zone used
Monitor
for asset protection. Works as a dynamic
monitor of a zone fault/trouble (not alarm).
Assigned sensors or contacts on doors and
General Monitor
windows or asset protection within the
premises. Used to track activity of the
occupant and alert occupant of the activity
of others.
Assigned sensors or contacts on doors and
General
windows or asset protection within the
Response
premises. Used to track activity of the
occupant and alert occupant of the activity
of others.
Used to monitor a resident in an area
Resident Monitor
deemed to be dangerous by a caregiver.
Used to monitor a resident in an area
Resident
Response
deemed to be dangerous by a caregiver.
Requires acknowledgement by caregiver.
Garage
Assigned to Automatic Garage Door
applications. Provides a status of the garage
(Burglary)
door close/open real time state.
Assigned to Automatic Garage Door
Garage Monitor
applications. Provides a status of the garage
door close/open real time state.
Zone Response Type Definitions (Continued)
Zone Response Type Definitions
Zone Response Type Definitions
Zone Response Type Definitions
Function
Function
Function
Function
be
used
with
heat
detectors,
Series wireless keys.
Lyric Controller Installation and Reference Guide
• Alarm sound will pulse (Temporal Fire) when this zone type is
alarmed and the alarm has been verified.
• System verifies alarm by delaying reporting and alarm
sounding for 30 seconds after alarm is detected. If the zone
remains faulted after 30 seconds a fire alarm is provided. If
any other fire zone is faulted during the 30 second delay
window a fire alarm is immediately provided for that zone.
An alarm for original fire zone will also be provided, if that
zone is still faulted. If there are no fire alarms after the 30
second delay expires, the system will open a 60 second
window. If any fire zone is faulted during that window a fire
alarm will immediately be provided for that zone.
• Exit delay regardless of the arming mode selected.
• System is armed in the Stay mode when the zone is
activated.
• System is armed in the Away mode when the zone is
activated.
• Disarms the system when the zone is activated.
No reports to the Central Station.
No keypad sounding or chime and no display on screen.
• System can still be armed.
Reports to the Central Station, if enabled.
Fault/restore events are logged by the system.
• Activity Zone No. and Zone Descriptor displayed on LCD.
Restore will be stored in event log.
No keypad sounding or chime.
System can still be armed.
• No reports to the Central Station.
• Fault/restore events are logged by the system.
• Monitors entry into a monitored area. Activates a one-time
announcement when faulted.
• Activity Zone No. and Zone Descriptor displayed on LCD.
• No reports to the Central Station.
• Fault/restore events are logged by the system.
• Monitors entry into a monitored area. Activates a zone
announcement when faulted.
• Activity Zone No. and Zone Descriptor displayed on LCD.
• System re-triggers audible sounding every ten seconds until
acknowledged.
• No reports to the Central Station.
• Monitors entry into a monitored area. Activates a zone
announcement when faulted.
• Activity Zone No. and Zone Descriptor displayed on LCD.
• Fault/Restore events are not logged by the system.
• No reports to the Central Station.
• Monitors entry into a monitored area. Activates a zone
announcement when faulted.
• Activity Zone No. and Zone Descriptor displayed on LCD.
• System re-triggers audible sounding every ten seconds until
acknowledged (Off sequence or wireless key).
• Fault/Restore events are not logged by the system.
• Associated With Entry Delay #2 Programmed Time.
• Exit delays when armed in Away, Stay or Night Stay mode.
• No Entry Delay when armed in Away or Stay Instant modes.
• System can be armed with zone in the faulted state. When the
zone is closed it will automatically be inclusive within
protection points. If the point is subsequently violated, it will
initiate an alarm.
• Can be assigned to any wireless zone used for automatic
"Garage Door" Open/Close status.
• Will not initiate an alarm condition on the controller.
• When zone is in the open state will display "FAULT."
• Does not report alarms to Central Station.
• Zone will chime if enabled.
System can be armed if this zone type is in fault.
- 21 -
(Continued)
(Continued)
(Continued)
Characteristics
Characteristics
Characteristics
Characteristics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lyric lcp500-l

Table of Contents