Advertisement

In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its
original condition and only parts identical to those specified should be used.
» ELECTRICAL SPECIFICATIONS ......................................................................................................... 1
» IMPORTANT SERVICE SAFETY PRECAUTION ................................................................................ 2
» LOCATION OF USER'S CONTROL ..................................................................................................... 6
» INSTALLATION AND SERVICE INSTRUCTIONS ............................................................................... 7
» CHASSIS LAYOUT ............................................................................................................................ 12
» BLOCK DIAGRAM ............................................................................................................................. 13
» DESCRIPTION OF SCHEMATIC DIAGRAMS ................................................................................... 14
» SCHEMATIC DIAGRAMS .................................................................................................................. 15
» PRINTED WIRING BOARD ASSEMBLIES ........................................................................................ 20
» REPLACEMENT PARTS LIST ........................................................................................................... 23
» PACKING OF THE SET ..................................................................................................................... 33
POWER INPUT ................................................... 120 V AC 60 Hz
POWER RATING .................................................................... 69 W
PICTURE SIZE ............................................. 580cm
CONVERGENCE ............................................................. Magnetic
SWEEP DEFLECTION ..................................................... Magnetic
FOCUS ............................................... Hi-Bi-Potential Electrostatic
INTERMEDIATE FREQUENCIES
Picture IF Carrier Frequency ..................................... 45.75 MHz
Sound IF Carrier Frequency ...................................... 41.25 MHz
Color Sub-Carrier Frequency ..................................... 42.17 MHz
AUDIO POWER
OUTPUT RATING ................................. 0.9W (at 10% distortion)

SHARP CORPORATION

SERVICE MANUAL

MODELS
CONTENTS

ELECTRICAL SPECIFICATIONS

SPEAKER
SIZE ...................................................................... 8 cm (Round)
VOICE COIL IMPEDANCE ............................... 8 ohm at 400 Hz
2
(89.8sq inch)
ANTENNA INPUT IMPEDANCE
VHF/UHF .................................................... 75 ohm Unbalanced
TUNING RANGES
VHF-Channels .............................................................. 2 thru 13
UHF-Channels ............................................................ 14 thru 69
CATV Channels .......................................................... 1 thru 125
(Nominal)
Specifications are subject to change without
prior notice.
This document has been published to be used for after
sales service only.
The contents are subject to change without notice.
1
COLOR TELEVISION
Chassis No. SN-80
13L-M100/150
CL13M10/15
14ML10
U.S.A.: (EIA, Channel Plan)
13L-M100/150
CL13M10/15
14ML10
S39E513L-M100
Page

Advertisement

Table of Contents
loading

Summary of Contents for Sharp CL13M10/15

  • Page 1: Table Of Contents

    13L-M100/150 CL13M10/15 14ML10 SERVICE MANUAL S39E513L-M100 COLOR TELEVISION Chassis No. SN-80 13L-M100/150 CL13M10/15 14ML10 MODELS In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
  • Page 2: Important Service Safety Precaution

    13L-M100/150 CL13M10/15 14ML10 IMPORTANT SERVICE SAFETY PRECAUTION Ë Service work should be performed only by qualified service technicians who are thoroughly familiar with all safety checks and the servicing guidelines which follow: WARNING X-RADIATION AND HIGH VOLTAGE LIMITS 1. For continued safety, no modification of any circuit 1.
  • Page 3: Safety Notice

    13L-M100/150 CL13M10/15 14ML10 IMPORTANT SERVICE SAFETY PRECAUTION (Continued) • Connect the resistor connection to all exposed metal BEFORE RETURNING THE RECEIVER parts having a return to the chassis (antenna, metal (Fire & Shock Hazard) cabinet, screw heads, knobs and control shafts, escutcheon and etc.) and measure the AC voltage...
  • Page 4 13L-M100/150 CL13M10/15 14ML10 PRECAUTIONS A PRENDRE LORS DE LA REPARATION Ne peut effectuer la réparation qu' un technicien spécialisé qui s'est parfaitement accoutumé à toute vérification de sécurité et aux conseils suivants. AVERTISSEMENT LIMITES DES RADIATIONS X ET DE LA HAUTE TENSION 1.
  • Page 5 13L-M100/150 CL13M10/15 14ML10 PRECAUTIONS A PRENDRE LORS DE LA REPARATION (Suite) • Toucher avec la sonde d'essai les pièces métalliques VERIFICATIONS CONTRE L'INCEN-DIE ET exposées qui présentent une voie de retour au LE CHOC ELECTRIQUE châssis (antenne, coffret métallique, tête des vis, Avant de rendre le récepteur à...
  • Page 6: Location Of User's Control

    13L-M100/150 CL13M10/15 14ML10 LOCATION OF USER'S CONTROL...
  • Page 7: Installation And Service Instructions

    13L-M100/150 CL13M10/15 14ML10 INSTALLATION AND SERVICE INSTRUCTIONS Note: (1) When performing any adjustments to resistor controls and transformers use non-metallic screwdrivers or TV alignment tools. (2) Before performing adjustments, the TV set must be on at least 15 minutes. HIGH VOLTAGE CHECK CIRCUIT PROTECTION The receiver is protected by a 4.0A fuse (F701),...
  • Page 8 13L-M100/150 CL13M10/15 14ML10 For adjustments of this model, the bus data is converted to various analog signals by the D/A converter circuit. Note: There are still a few analog adjustments in this series such as focus and master screen voltage.
  • Page 9 13L-M100/150 CL13M10/15 14ML10 DATA SERVICE ADJUSTMENT ITEM ADJUSTMENT CONTENTS NUMBER RANGE INITIAL VALUE PICTURE 00-7F TINT 00-7F COLOR 00-7F BRIGHTNESS 00-7F SHARPNESS 00-3F Must be set to "24" VERTICAL PHASE 00-07 Must be set between "0" and "03" HORIZONTAL PHASE...
  • Page 10: Service Adjustment

    13L-M100/150 CL13M10/15 14ML10 SERVICE ADJUSTMENT VCO Adjustment White Balance Adjustment 1. Connect a digital voltmeter between pin (44) of IC201 1. Receive a good local channel. and ground. 2. Enter the service mode and select the service 2. Select a good local channel.
  • Page 11 13L-M100/150 CL13M10/15 14ML10 Sub-Brightness Adjustment 3.58MHz Trap Adjustment 1. Receive a good local channel. 1. Receive a good local channel. 2. Make sure the customer brightness control is set to 2. Enter the service mode and select the service center position.
  • Page 12: Chassis Layout

    13L-M100/150 CL13M10/15 14ML10 CHASSIS LAYOUT PWB-B PWB-A...
  • Page 13: Block Diagram

    13L-M100/150 CL13M10/15 14ML10 BLOCK DIAGRAM...
  • Page 14: Description Of Schematic Diagrams

    13L-M100/150 CL13M10/15 14ML10 DESCRIPTION OF SCHEMATIC DIAGRAM WAVEFORM MEASUREMENT CONDITIONS: NOTES: 1. Photographs taken on a standard gated color bar 1. The unit of resistance "ohm" is omitted. (K=k Ω =1000 Ω , M=M Ω ) signal, the tint setting adjusted for proper color. The wave shapes at the red, green and blue cathodes of 2.
  • Page 15: Schematic Diagrams

    13L-M100/150 CL13M10/15 14ML10 SCHEMATIC DIAGRAM: CRT Unit Ë 13L-M100/150, CL13M10/15 Ë 14ML10...
  • Page 16 13L-M100/150 CL13M10/15 14ML10 MODELS 13L-M100/150, CL13M10/15 SCHEMATIC DIAGRAM: MAIN Unit PWB-A (DUNTK9529WEW1)···(13L-M100/150) (DUNTK9529WEW3)···(CL13M10/15) (13L-M100, CL13M10) (13L-M150, CL13M15)
  • Page 17 13L-M100/150 CL13M10/15 14ML10...
  • Page 18 13L-M100/150 CL13M10/15 14ML10 MODEL 14ML10 SCHEMATIC DIAGRAM: MAIN Unit...
  • Page 19 13L-M100/150 CL13M10/15 14ML10...
  • Page 20: Printed Wiring Board Assemblies

    13L-M100/150 CL13M10/15 14ML10 PRINTED WIRING BOARD ASSEMBLIES PWB-A: MAIN Unit (Wiring Side)
  • Page 21 13L-M100/150 CL13M10/15 14ML10 PWB-A: MAIN Unit (Chip Parts Side)
  • Page 22 13L-M100/150 CL13M10/15 14ML10 PWB-B: CRT Unit (Wiring Side) PWB-B: CRT Unit (Chip Parts Side)
  • Page 23: Replacement Parts List

    4. DESCRIPTION in USA: Contact your nearest SHARP Parts Distributor to order. in CANADA: Contact SHARP Electronics of Conada Limited For location of SHARP Parts Distributor, Please call Toll- Phone (416) 890-2100 Free; 1-800-BE-SHARP MARK : SPARE PARTS-DELIVERY SECTION MARQUE: SECTION LIVRAISON DES PIECES DE RECHANGE...
  • Page 24 Part No. Description Code Ref. No. Part No. Description Code PWB-A : DUNTK9529WEW1(13L-M100/150) D762 RH-DX0441CEZZ J Diode å PWB-A : DUNTK9529WEW3(CL13M10/15) MAIN UNIT (Continued) RH-DX0110CEZZ D763 VHD1SS119//-1 J Diode Q351 VS2PD601AR/-1 J 2PD601AR D901 RH-EX0630GEZZ J Zener Diode, 9.1V Q401...
  • Page 25 Description Code Ref. No. Part No. Description Code PWB-A : DUNTK9529WEW1(13L-M100/150) C706 RC-KZ0092GEZZ J 0.0033 Ceramic å AC125V PWB-A : DUNTK9529WEW3(CL13M10/15) RC-KZ0311CEZZ MAIN UNIT (Continued) C707 VCEAGA2CW226M J 22 160V EL. C305 VCKYPA1HB151K J 150p 50V Ceramic å C712 RC-EZ0638CEZZ J 33 160V EL.
  • Page 26 Description Code Ref. No. Part No. Description Code PWB-A : DUNTK9529WEW1(13L-M100/150) R603 VRS-VV3LB270J J 27 M-Ox. å PWB-A : DUNTK9529WEW3(CL13M10/15) R605 VRN-MD2AL332J J 3.3k 1/10W M-Film R606 VRD-RA2BE102J J 1.0k 1/8W Carbon MAIN UNIT (Continued) R608 VRD-RA2BE101J J 100 1/8W...
  • Page 27: Main Unit

    Description Code Ref. No. Part No. Description Code PWB-A : DUNTK9529WEW1(13L-M100/150) PWB-A : DUNTK9529WEW5(14ML10) PWB-A : DUNTK9529WEW3(CL13M10/15) MAIN UNIT MAIN UNIT (Continued) R2045 VRN-MD2AL101J J 100 1/10W M-Film TUNER R2047 VRN-MD2AL221J J 220 1/10W M-Film NOTE : THE PARTS HERE SHOWN ARE SUPPLIED AS AN R2048 VRD-RA2BE562J J 5.6k 1/8W...
  • Page 28 13L-M100/150 CL13M10/15 14ML10 Ref. No. Part No. Description Code Ref. No. Part No. Description Code T701 RTRNP0527CEZZ J Power Transformer PWB-A : DUNTK9529WEW5(14ML10) å MAIN UNIT (Continued) RTRNP0518CEZZ D641 RH-EX0630GEZZ J Zener Diode, 9.1V CAPACITORS D651 RH-DX0131CEZZ J Diode çå...
  • Page 29 13L-M100/150 CL13M10/15 14ML10 Ref. No. Part No. Description Code Ref. No. Part No. Description Code RJ20 VRS-CY1JF000J 1/16W M-Ox. PWB-A : DUNTK9529WEW5(14ML10) RJ21 VRS-CY1JF000J 1/16W M-Ox. MAIN UNIT (Continued) RJ23 VRS-CY1JF000J 1/16W M-Ox. RJ24 VRS-CY1JF000J 1/16W M-Ox. C662 VCEA0A1CW477M J 470...
  • Page 30 13L-M100/150 CL13M10/15 14ML10 Ref. No. Part No. Description Code Ref. No. Part No. Description Code R2001 VRD-RA2BE102J J 1.0k 1/8W Carbon PWB-A : DUNTK9529WEW5(14ML10) R2002 VRS-CY1JF103J J 10k 1/16W M-Ox. MAIN UNIT (Continued) R2006 VRS-CY1JF103J J 10k 1/16W M-Ox. R2007 VRD-RA2BE223J...
  • Page 31: Crt Unit

    14ML10 Ref. No. Part No. Description Code Ref. No. Part No. Description Code PWB-B : DUNTK9530WEW1 PWB-A : DUNTK9529WEW5(14ML10) (13L-M100/150, CL13M10/15) MAIN UNIT (Continued) CRT UNIT J903 QJAKE0159CEZZ J Jack, Audio IN TRANSISTORS J905 QJAKE0158CEZZ J Jack, Video IN Q852...
  • Page 32: Supplied Accessories

    Infrared R/C Unit (14ML10) AT Q881 VS2SA1266-Y-1 J 2SA1266(Y) TGAN-0018PEZZ R Guarantee Card (13L-M100/150) AD TiNS-6571PEZZ R Operation Manual (13L-M100/150) AD VS2SA1015-Y-1 TiNS-6572PEZZ R Operation Manual (CL13M10/15) AD TiNS-6573PEZZ R Operation Manual (14ML10) DIODES PACKING PARTS D881 VHD1SS119//-1 J Diode D882 VHD1SS119//-1...
  • Page 33: Packing Of The Set

    13L-M100/150 CL13M10/15 14ML10 Ref. No. Part No. Description Code Ref. No. Part No. Description Code PACKING OF THE SET Polyethylene Bag Operation Manual Guarantee Card Batteries Wrapping Paper Buffer Material FRONT Packing Case Use tapes to fix the packing case.
  • Page 34 Code Ref. No. Part No. Description Code COPYRIGHT © 1999 BY SHARP CORPORATION ALL RIGHTS RESERVED. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher.

This manual is also suitable for:

14ml1013l-m100/15013l-m10013l-m150Cl13m10Cl13m15

Table of Contents