3.Fusing section

No.
A
Fusing unit
B
Thermostat
C
Thermistor
D
Heater lamp
E
Upper heat roller
F
Separation pawl
G
Lower heat roller
H
Separation pawl
A.Fusing unit removal
(1)
B.Thermostat
(1)
(2)
Contents
(1)
(3)
(2)
M4×14
(2)
M3×10
(2)
(3)
AR-5520 DISASSEMBLY AND ASSEMBLY 11-4
C.Thermistor
Installation: When installing the thermistor, be sure to face the installing
projection (A) toward the installing surface.
Check that the thermistor is in contact with the upper heat
roller.
(A)
D.Heater lamp
Assembly: Insert the spring (A) into the hole (B) in the fusing frame.
(1)
(2)
Assembly: Put the paper guide earth spring (A) under the paper guide
(B) before fusing.
(A)
(B)
(1)
(1)
(2)
(B)
(A)
(2)
(1)
(2)