(2)
To clear the MJ/MN alarm by external key
START
CM05
Assign a Unit and Slot number to the DLC
blade.
NOTE:
CM10
Assign the station number connected to
PGD(2)-U10 ADP to its associated Physical
Port number.
CM12
Assign the Kind of PGD(2)-U10 station.
Specify the External Key group number.
CM13
Allow the accommodation of PGD(2)-U10
ADP.
NOTE1:
NOTE2:
A
DESCRIPTION
BLADE RESET
When the PGD(2)-U10 ADP is
accommodated to the Remote Unit,
execute the system data copy by
CMEC Y=8 before executing the
blade reset.
BLADE RESET
Set this data only for a Base Port of DLC blade.
Whether the following equipments can be accommodated to the same DLC blade or not
are depended on this data.
- When the second data is set to "0"
Accommodatable
: DT300/D
Unaccommodatable : D
- When the second data is set to "1"
Accommodatable
: DT300/D
Unaccommodatable : D
Chapter 1 MAINTENANCE SERVICES
•
Y=0
(1)
XX ZZ
XX: 01-50: Unit No.
ZZ : 01-18: Slot No.
(2)
10: DLC blade
•
Y=00
(1)
XX YY ZZ: Physical Port No.
XX: 01-50: Unit No.
YY: 01-18: Slot No.
ZZ : 01-32: Circuit No.
(2)
FX-FXXXXXXXX: Station No.
•
Y=65
(1)
X-XXXXXXXX: Station No.
(2)
3: External relay/external key only
•
Y=66
(1)
X-XXXXXXXX: Station No.
(2)
00-63 : External Key Group No.
•
Y=63
(1)
X-XXXXXXXX: Station No.
(2)
0 : To accommodate
1 : Not accommodated
term
term
85/D
70/PGD(2)-U10 ADP
term
75/DESKCON
term
term
85/D
75/DESKCON
term
70/PGD(2)-U10 ADP
1-13
FAULT MESSAGE
DATA
NWA-033627-001 Rev.4.0
95ch1001.fm
APRIL/16/2010