Drip Tray - Philips EP5961 User Manual

Super automatic espresso machine 5000 series
Hide thumbs Also See for EP5961:
Table of Contents

Advertisement

Problem
The machine is in DEMO
mode.
The 'coffee grounds
container full' icon
remains displayed.
I cannot remove the
brew group.
I cannot insert the brew
group.
The coffee is watery.
The coffee is not hot
enough.
Cause
You pressed the standby
button for more than 8
seconds.
You emptied the coffee
grounds container while the
machine was switched off.
You placed back the coffee
grounds container too early.
The brew group is not in the
correct position.
You have not removed the
coffee grounds container.
The brew group is not in the
correct position.
The machine is still in the
descaling procedure.
The grinder is set to a too
coarse setting.
The coffee exit duct is clogged.
The machine is performing its
self-adjustment procedure.
The brew group is dirty or
needs to be lubricated.
The cups you use are cold.
The temperature is set too low.
Check the menu settings.
Solution
Switch the machine off and then on
again with the main switch on the back
of the machine.
Always empty the coffee grounds
container while the machine is switched
on. If you empty the coffee grounds
container when the machine is switched
off, the coffee cycle counter is not reset.
Do not place back the coffee grounds
container until the screen prompts you
to put it back.
Reset the machine in the following way:
place back the drip tray and the coffee
grounds container. Then close the
service door and switch the machine off
and back on again. Try again to remove
the brew group.
Remove the coffee grounds container
before you remove the brew group.
Reset the machine in the following way:
place back the drip tray and the coffee
grounds container. Leave the brew
group out. Close the service door and
switch the machine on and off. Then put
the brew group in the correct position
and reinsert it into in the machine.
You cannot remove the brew group
when the descaling procedure is in
progress. First complete the descaling
procedure and then remove the brew
group.
Set the grinder to a finer (lower) setting.
Clean the coffee exit duct with the
spoon handle. Then switch the machine
off and on again.
Brew a few cups of coffee.
Clean and lubricate the brew group.
Preheat the cups by rinsing them with
hot water.
Set the temperature to 'high' in the
menu.
English
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep5960Ep5365Ep5364Ep5363Ep5360Ep5361

Table of Contents