Remote Leds And Recovery Switch; Cables And Connectors; Remote Led And Recovery Switch Wiring - Motorola MOTOWI 4 User Manual

Point-to-point wireless solutions
Table of Contents

Advertisement

3.3.4 Remote LEDs and Recovery Switch

The PTP 500 Series Bridge PIDU Plus provides a facility to connect remote LEDs and Recovery
switch allowing the PIDU Plus to be mounted inside an enclosure. At the left hand end of the PIDU
Plus under the ODU connection cover can be found a PCB header and three jumpers. Jumpers
J906 and J907 should be removed and connection to the remote LEDs and Recovery switch made
to J908 as shown in

3.3.5 Cables and connectors

The cable used to connect the PTP 500 Series Bridge PIDU Plus to the ODU can be any standard
CAT5e type provided that it is suitable for outdoor deployment. Motorola recommends that cables
to the specification below be used:
Cable:
Connector Type:
Gland:
Getting Started
Figure
10.
Figure 10 Remote LED and Recovery Switch Wiring
Superior Essex BBDGE CAT 5e
Tyco, 5-558530-1
Motorola WB1811
29