CHECKING OPEN ZONES
Checking Zones: Before arming your system, all protected doors, windows and other
detection zones must be closed or bypassed; otherwise the keypad displays "Not Ready."
GOTO: If the user is authorized, a keypad in one partition can be used to perform system
functions in the other partition by using the GOTO command.
Mode
Press these keys...
What happens
• Displays all faulted zones.
CHECK
∗ ∗ ∗ ∗
ZONES
• The keypad beeps to confirm the partition
4-digit code +
+ partition no.:
∗ ∗ ∗ ∗
change.
1 or 2 (Vista-32FBPT);
GOTO
• Keypads automatically return to their
1 through 8 (Vista-128FBPT/Vista-
original partition after 2 minutes with no
250FBPT) = go to partition;
0 = return to home part
keypad activity.
ARMING THE SYSTEM, CHIME MODE, and CONTROLLING DEVICES
Before arming, close all perimeter doors and windows and make sure the Ready to Arm
message is shown.
After arming, leave the premises through an entry/exit door during the exit delay period and
be sure the door is reclosed to avoid causing an alarm.
Mode
Press these keys...
When to use an arming mode and what happens
• Used when staying on premises, but someone
might use the entrance door later.
• Arms the perimeter.
• An alarm sounds if a protected window or any door
is opened.
4-digit code +
3
When armed in STAY mode, the system will sound an
+
1
for STAY
alarm if a protected door or window is opened, but
Mode 1.
you may otherwise move freely throughout the
premises. Arrivals can enter through the entrance
door without causing an alarm, but must disarm the
4-digit code +
3
system within the entry delay period or an alarm will
occur.
+
2
for STAY
The system provides three STAY modes. STAY mode
STAY
Mode 2.
1, 2, and 3. When activated, STAY modes 1 and 2
automatically bypass specific zones assigned by your
installer to each of the STAY modes. STAY mode 3,
when activated, automatically bypasses all zones
4-digit code +
3
assigned to STAY modes 1 AND 2. Check with your
+
3
for STAY
installer for a list of the zones that are bypassed
during each STAY mode.
Mode 3.
NOTE: If none of the zones in a partition are
assigned to Stay mode 2, then when the user enters
Three beeps confirm.
[User Code] + [3] (STAY), all zones assigned to
Stay mode 1 are automatically bypassed.
The keypad beeps three times, displays the armed
message, and indicates which STAY mode (1, 2 or 3).
• Used when nobody is staying inside.
4-digit code +
2
• Arms the entire system (interior and perimeter).
AWAY
• An alarm sounds if a protected window or any door
two beeps confirm
is opened, or if any movement is detected inside.
• Used when leaving the premises for extended
4-digit code +
4
periods (e.g., vacation).
MAXIMUM
• Same as Away mode, except entry delay is off.
two beeps confirm
• An alarm sounds same as Away mode, and sounds
upon opening entry/exit doors.
QUICK
• If programmed, you can press the [#] key in place
# + arming key
ARMING
of your security code when arming the system
• Alerts you to the opening of a perimeter door or
4-digit code +
9
window while the system is disarmed.
CHIME
• Three tones sound at the keypad whenever a
MODE
(enter again to turn
perimeter door or window is opened (interior zones
Chime mode off)
do not produce a tone when they are faulted).
• Pressing the READY key displays the open zones.
Activate output device as programmed.
4-digit code +
#
Enter 71 or 72.
CONTROL
Activate output device manually
4-digit code +
#
OUTPUT
DEVICE
Enter 70.
Activate output device or system event instantly
4-digit code +
#
Enter 77.
Randomize output devices set for random
4-digit code +
#
schedules
Enter 41
Randomize output devices set for random
RANDOMIZE
4-digit code +
#
schedules with activation times between 6 PM and
OUTPUT
Enter 42.
5 AM
DEVICE
Enter the sequence
De-activate randomization
used to activate
randomization.
DISARMING THE SYSTEM and SILENCING ALARMS
The 1 OFF key is used to disarm the system, silence alarm and trouble sounds, and clear
memory of alarm displays.
Mode
Press these keys...
What happens
• System is disarmed and alarm sounding is silenced.
DISARM
• To clear the memory of alarm display (if present),
and
4-digit code + 1
enter your 4-digit code + 1 again.
SILENCE
ALARMS
BYPASSING ZONES
Use the 6 BYPASS key when you want to arm your system with one or more zones
intentionally unprotected.
Mode
Press these keys... What happens
• When finished, the keypad will momentarily display a
"Bypass" message for each bypassed zone number.
Wait for all bypassed zones to be displayed.
• Arm the system as usual. When armed, the arming
4-digit code + 6 +
BYPASS
message is displayed with "ZONE BYPASSED."
3-digit zone numbers
ZONES
• Bypassed zones are unprotected and will not cause
to be bypassed
an alarm if violated.
• The system may not allow fire zones to be bypassed.
• Zones may be automatically unbypassed when the
system is disarmed.
PANIC KEYS
Your system may have been programmed to use special keys or key pairs to manually
activate emergency (panic) functions as follows:
This Function
Key(s)*
Sends This Signal**
With This Sounding...
Silent Alarm
silent alarm
no change to the keypad.
Audible Alarm
audible alarm
a loud, steady alarm at keypad(s) and
at any external sounders that may be
connected.
Personal Alarm
auxiliary alarm
steady alarm sound at keypad(s), but
not at external bells or sirens.
Fire Alarm
fire alarm
temporal (pulsing) sound at external
bells and sirens.
* Enter the appropriate keys programmed by your installer for each function (see installer).
** All panic functions send signals to the Central Monitoring Station, if connected.
To activate a Panic Function:
Keys
Press and hold down for at least 2 seconds
[A]
the programmed lettered key or key pair
[B]
for the desired emergency function (or
[C]
press both keys of the assigned key pair at
SHIFT
FUNCTION
WHEN LIT
• When entering codes and commands, sequential key depressions must be made within 4-5
seconds of one another. If 4-5 seconds elapse without a key depression, the entry will be
aborted and must be repeated from its beginning.
• If you make a mistake while entering a security code, stop, press the
start over. If you stop in the middle while entering a code, and then immediately start the
entry over, an erroneous code might be entered.
SECURITY CODES
Your installer assigned a master code that is used to perform all system functions.
In addition, other security codes can be assigned for use by other users.
• Only the Master and Manager Codes can assign security codes to users.
• Users are identified by a 2-digit user number (Vista-32FBPT) or 3-digit user number
(Vista-128FBPT/Vista-250FBPT).
• In addition to a security code, each user is assigned an authority level and various system
attributes. See the full User Guide for definitions of each Authority Level.
• Security codes can be used interchangeably within a partition when performing system
functions (a system armed with one security code can be disarmed by a different security
code), with the exception of the Guest codes.
• Security code programming involves these steps:
1. Choose a user number from the set of users assigned to the partition in which the user
will be operating, and assign a 4-digit security code.
2. Assign an authority level to that user.
3. Assign other attributes as necessary.
Assigning Security Codes and User Attributes
The following lists the various command strings for adding security codes and attributes.
Function
Add Security Code
Delete Security
Code
Change a User
Security Code
Pairs
Displayed as Zone
(∗ ∗ ∗ ∗ /1)
995
(∗ ∗ ∗ ∗ /#)
999
(3/#)
996
A
B
C
ARMED
1
2
3
(A)
BS/ESC
OFF
AWAY
STAY
READY
D
E
F
4
5
6
(B)
POWER
/
MAX
TEST
BYPASS
ALARM
S
T
X
SILENCED
7
8
9
(C)
N / Y
INSTANT
CODE
CHIME
SUPV
SPACE
ENTER
TROUBLE
(D)
READY
0
#
SHIFT
key, and then
∗ ∗ ∗ ∗
Commands
Master or Manager code + 8
+ [user no.] + new user's security
code
Follow the screen prompts to add the authority level and other attributes for
this user. The Keypad beeps once to confirm that new user was added.
Master or Manager code + 8
+ [user no.] + Master or Manager code
first entered.
When prompted, press 1 (YES).
The security code set for this user number is erased from the
system.
Master code + 8 + [user no.]. Enter the new code for that user.
When prompted, press 0 (NO).
The security code set for this user number is changed to the new
code.