Specifications; Electrical Data; Measurement; Refrigerant Charge - Fujitsu AOU36RLXFZ Service Manual

Inverter multi air conditioner
Hide thumbs Also See for AOU36RLXFZ:
Table of Contents

Advertisement

S P E C I FI C AT ION S
OUTDOOR UNIT

ELECTRICAL DATA

TYPE
MODEL NAME
POWER SUPPLY
FREQUENCY
Cooling
AIR
CIRCULATION
Heating
Cooling
NOISE LEVEL
Heating
FAN MOTOR
DISCRIMINATION
Cooling
HIGH SPEED
Heating
COMPRESSOR
TYPE
DISCRIMINATION
WEIGHT
PRECHARGED REFRIGERANT
REFRIGERANT TYPE

MEASUREMENT

DIMENSIONS
H x W x D
WEIGHT
Net / Shipping
4 room multi inverter
AOU36RLXFZ
208 V / 230 V
60 Hz
3
2,119 cfm (3,600 m
/h)
3
2,237 cfm (3,800 m
/h)
53 dB
55 dB
MFE-45VVT
850 r.p.m.
900 r.p.m.
Hermetic type, Inverter,
4 poles, 3 phase,
DC motor, Twin Rotary
TNB220FPBMT
31 lbs 8-1/2 oz (14.3 kg)
7 lbs 4-7/16 oz (3,300 g)
R410A
32-11/16 x 35-7/16 x 13 inch
(830 x 900 x 330 mm)
149 lbs / 165 lbs
(68 kg / 75 kg)

REFRIGERANT CHARGE

(When 3 or 4 indoor units are connected)
Total pipe length
ADDITIONAL CHARGE
ADDITIONAL CHARGE
MAXIMUM PIPE LENGTH (total)
MINIMUM PIPE LENGTH (total)
MAXIMUM PIPE LENGTH (each unit)
MINIMUM PIPE LENGTH (each unit)
MAX ELEVATION (between indoor units)
MAX ELEVATION (between indoor and outdoor units)
REFRIGERANT CHARGE
(When 2 indoor units are connected)
Total pipe length
ADDITIONAL CHARGE
ADDITIONAL CHARGE
MAXIMUM PIPE LENGTH (total)
MINIMUM PIPE LENGTH (total)
MAXIMUM PIPE LENGTH (each unit)
MINIMUM PIPE LENGTH (each unit)
MAX ELEVATION (between indoor units)
MAX ELEVATION (between indoor and outdoor units)
164 ft (50 m)
(None)
197 ft (60 m)
8-13/16 oz (250 g)
230 ft (70 m)
1 lb 1-5/8 oz (500 g)
9/32 oz/ft (25 g/m)
230 ft (70 m)
66 ft (20 m)
82 ft (25 m)
16 ft (5 m)
33 ft (10 m)
49 ft (15 m)
66 ft (20 m)
(None)
98 ft (30 m)
8-13/16 oz (250 g)
131 ft (40 m)
1 lb 1-5/8 oz (500 g)
9/32 oz/ft (25 g/m)
131 ft (40 m)
49 ft (15 m)
82 ft (25 m)
25 ft (7.5 m)
33 ft (10 m)
49 ft (15 m)

Hide quick links: