2-5. SERVICE POSITION
Chassis assy
• REMOVAL OF ANODE-CAP
NOTE:
Short circuit the anode of the picture tube
and the anode cap to the metal chassis, CRT shield
or carbon paint on the CRT, after removing the
anode.
• REMOVING PROCEDURES
CD
Turn up one side of the rubber cap in the direction indicated
by the arrow®.
®
Using a thumb pull up the rubber cap firmly in the direction
indicated by the arrow®.
@
When one side of the rubber cap is separated from the anode
button, the anode-cap can be removed by turning up the
rubber cap and pulling up it in the direction of the arrow
@.
• HOW TO HANDLE AN ANODE.CAP
CD
Don't hurt the surface of anode-caps with sharp shaped
material!
®
Don't press the rubber hardly not to hurt insilie of anode-
caps! A material fitting called as shatter-hook terminal is
built in the rubber.
@
Don't turn the foot of rubber over hardly! The shatter-hook
terminal will stick out or hurt the rubber.