Download Print this page

Philips PAR-56 Specifications page 2

Tungsten halogen lamps, mogul end prong and extended mogul end prong bases (par-64 and par-56)

Advertisement

Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Printed in USA 07/05
Tungsten Halogen PAR Lamps
Electrical,Technical and Ordering Data
Product
ANSI
Number
Description
Code
35619-6
500PAR56Q/NSP
35621-2
500PAR56Q/MFL
35620-4
500PAR56Q/WFL
27555-2
1000PAR64Q/NSP
27556-0
1000PAR64Q/MFL
27558-6
1000PAR64Q/WFL
34350-9
1000PAR64QVNSP
FFN
34351-7
1000PAR64QNSP
FFP
34352-5
1000PAR64QMFL
FFR
34353-3
100PAR64QWFL
FFS
1) Beam Spread to 50% peak candlepower.
2) Candlepower Average in central 5˚ cone for spot to 10˚ cone for flood.
3) Rated Average Life is the length of operation (in hours) at which point an average of 50% of the lamps will still be operational and 50% will not.
Note: Lamps can be operated in ANY position.
Operation & Handling
Studio and theater lamps require care to gain
optimum performance with every use. Handling
the glass of a quartz lamp should be avoided. It is
advisable to use gloves when touching a lamp.
Should the lamp be touched, careful cleaning can
be done with a solvent such as alcohol. Shielding
of halogen lamps is generally considered an
advisable precaution.
Average Performance Characteristics
Fig. 1 and Fig. 2 — Data becomes more
inaccurate beyond 80–120%. Overvolting Stage
and Studio lamps can result in immediate failure;
undervolting increases live expectancy while
reducing color temperature.
Type
Diameter
(In.)
500PAR56Q/NSP
7
500PAR56Q/MFL
7
500PAR56Q/WFL
7
1000PAR64Q/NSP
8
1000PAR64Q/MFL
8
1000PAR64Q/WFL
8
FFN
8
FFP
8
FFR
8
FFS
8
www.philips.com
P-1223-D
(Subject to change without notice)
Std.
Heat
Pkg.
Resistant
Watts
Qty. Volts
Description
500
8
120
Narrow Spot
500
8
120
Med. Flood
500
8
120
Wide Flood
1000
8
120
Narrow Spot
1000
8
120
Med. Flood
1000
8
120
Wide Flood
1000
8
120
Very Narrow Spot
1000
8
120
Narrow Spot
1000
8
120
Med. Flood
1000
8
120
Wide Flood
Fig. 1 Variation of life characteristics
with applied voltage
300
260
220
180
140
100
60
20
88
92
Percentage Rated Volts
M.O.L.
(In.)
5
5
5
6
6
6
6
6
6
6
Bulb
Beam
Type
Base
Angle
PAR-56
Mog. End
17 x 34
PAR-56
Mog. End
20 x 48
PAR-56
Mog. End
28 x 70
PAR-64
Ext. Mog End
16 x 28
PAR-64
Ext. Mog End
24 x 44
PAR-64
Ext. Mog End
42 x 76
PAR-64
Ext. Mog End
12 x 6
PAR-64
Ext. Mog End
14 x 7
PAR-64
Ext. Mog End
28 x 12
PAR-64
Ext. Mog. End
55 x 22
Fig. 2 Variation of light characteristics
140
100
60
20
96
100
104
108
Diameter
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
Rated
Average Approx.
Candle-
Initial
Life
1
2
Power
Lumens
(Hrs.)
3
88,000
3500
4000
47,000
3800
4000
22,500
5000
4000
200,000
9800
4000
80,000
12,000
4000
31,000
14,800
4000
400,000
11,000
800
330,000
12,000
800
120,000
14,000
800
40,000
19,000
800
with applied voltage
Watts
Lumens
88
92
96
100
104
Percentage Rated Volts
Color
Temp.
3000
3000
3000
3000
3000
3000
3200
3200
3200
3200
108

Advertisement