Page 3
Our lamps aim to meet some or all of these values. It provides a reference guide to the light properties of the full range of Philips lamps for outdoor lighting, and also indicates the application areas for which their benefits are most applicable.
Page 5
HID Lamps Urban architectural lighting of buildings, bridges, statues and gardens can also help to create a nightscape even more striking than the same area as seen by day. Today’s architectural lighting does not necessarily involve high light levels but models architectural features with color and shade.
Page 6
MHN-SA lamps require UV-absorbing and protective front glass and ● correct thermal behaviour for optimal lamp performance Environment This product is RoHS compliant ● This product is covered by WEEE ● Recommended gear page 3.170 www.philips.com/OEM Type MASTER MHN-SA 1800W/956 (P)SFC 230V UNP CMax DMax ONom...
Page 8
MASTER MHN-SA Spectral power distribution MHN-SA 1800W 230V MHN-SA 2000W /956 400V Performance diagram Lamp performance during run up MHN-SA Lumen maintenance diagram 1000 2000 MHN-SA 1800W /856/956 230V/400V OEM Catalogue 2009/2010 [nm] MHN-SA 1800W /956 400V [nm] 3000 4000 5000 Burning hours...
Page 9
Life expectancy diagram 1000 2000 3000 MHN-SA 1800W /856/956 230V/400V Cap Base Operating position (P)SFC 4000 5000 1000 Burning hours MHN-SA 2000W /956 400V MASTER MHN-SA 2000 3000 4000 5000 Burning hours OEM Catalogue 2009/2010...
Page 10
MHN-LA lamps require UV-absorbing and protective front glass and ● correct thermal behaviour for optimal lamp performance Environment This product is RoHS compliant. ● This product is covered by WEEE ● Recommended gear page 3.170 www.philips.com/OEM ANom DMax ONom XNom 40.5...
Page 11
MHN-LA 1000W Technical data Type MASTER MHN-LA 1000W/842 230V XWH UNP MASTER MHN-LA 2000W/842 400V XWH UNP MASTER MHN-LA 2000W/956 400V XWH UNP Light data Type MASTER MHN-LA 1000W/842 230V XWH UNP MASTER MHN-LA 1000W/956 230V XWH UNP MASTER MHN-LA 2000W/842 400V XWH UNP MASTER MHN-LA 2000W/956 400V XWH UNP Ordering and packing data Type...
Page 12
MASTER MHN-LA MHN-LA 2000W /842 400V Performance diagram Operating position Lamp performance during run up MHN-LA Lumen maintenance diagram 2000 4000 MHN-LA 1000W /842/956 230V Life expectancy diagram 2000 4000 MHN-LA 1000W /842/956 230V 3.12 OEM Catalogue 2009/2010 [nm] MHN-LA 2000W /956 400V 6000 8000...
Page 14
Good colour rendering for a pleasant ambience with high visual ● comfort Application Semi-professional sports, area and floodlighting ● Luminaires Requires UV-absorbing and protective front glass ● Correct thermal conditions are required for optimal lamp ● performance Recommended gear page 3.170 www.philips.com/OEM ANom CMin DMax ONom XNom...
Page 15
Technical data Type MHN-SB 2000W/956 400V K12s-7 WH UNP Light data Type MHN-SB 2000W/956 400V K12s-7 WH UNP Ordering and packing data Type MHN-SB 2000W/956 400V K12s-7 WH UNP MN-2000-E-Cable-/H Spectral power distribution MHN-SB 2000W /956 Lumen maintenance diagram 1000 2000 3000 MHN-SB 2000W /956...
Page 16
Application Sports lighting, floodlighting of buildings and monuments, area ● lighting e.g. harbours and building sites Luminaires HPI-T lamps require a protective front glass ● Recommended gear page 3.170 www.philips.com/OEM Type CMax HPI-T 1000W/643 E40 220V CRP DMax LNom ONom...
Page 17
HPI-T 2000W HPI-T 1000W Technical data Type Lamp Current HPI-T 1000W/643 E40 220V CRP 8.25 HPI-T 2000W/642 E40 380V CRP HPI-T 2000W/646 E40 220V CRP 16.5 Light data Type HPI-T 1000W/643 E40 220V CRP HPI-T 2000W/642 E40 380V CRP HPI-T 2000W/646 E40 220V CRP Ordering and packing data Type HPI-T 1000W/643 E40 220V CRP...
Page 18
HPI-T CRV diagram Performance diagram Lamp performance during run up HPI-T 1000W HPI-T HPI-T 1000W/2000W Lumen maintenance diagram 2000 4000 HPI-T 1000W/2000W /643/646 Life expectancy diagram 2000 4000 HPI-T 1000W/2000W /643/646 Cap Base Operating position 3.18 OEM Catalogue 2009/2010 6000 8000 10000...
Page 20
The results in both light output and colour temperature are different Environment Good environmental choice because of long service life ● This product is RoHS compliant ● This product is covered by WEEE ● Recommended gear page 3.170 www.philips.com/OEM CMax DMax LNom ONom 46.5 46.5...
Page 21
Technical data Type MASTER HPI-T Plus 250W/645 E40 SLV MASTER HPI-T Plus 400W/645 E40 SLV Light data Type MASTER HPI-T Plus 250W/645 E40 SLV MASTER HPI-T Plus 400W/645 E40 SLV Ordering and packing data Type MASTER HPI-T Plus 250W/645 E40 SLV MT-250/45/2B-H-E40-/H MASTER HPI-T Plus 250W/645 E40 SLV MT-250/45/2B-H-E40-/H...
Page 22
MASTER HPI-T Plus Performance diagram Lamp performance during run up HPI-T Lumen maintenance diagram 4000 8000 HPI-T 250W/400W /643/645 Photometric diagram HPI-T Cap Base Operating position 3.22 OEM Catalogue 2009/2010 Life expectancy diagram 12000 16000 20000 Burning hours HPI-T 250W/400W /643/645 4000 8000 12000...
Page 23
MASTER HPI-T Plus OEM Catalogue 2009/2010 3.23...
Page 24
HPI Plus BUS and BUS-P types require an HPL-gear and no ignitor ● Environment Good environmental choice because of long service life ● This product is RoHS compliant ● This product is covered by WEEE ● Recommended gear page 3.170 www.philips.com/OEM...
Page 25
Technical data Type MASTER HPI Plus 250W/745/767 BU E40 CRP/SLV MASTER HPI Plus 400W/745/767 BU(-P) (BUS) E40 CRP/SLV MASTER HPI Plus 400W/745 HOR E40 CRP MASTER HPI Plus 400W/745 BUS E40 CRP/SLV Light data Type MASTER HPI Plus 250W/745 BU E40 CRP/SLV MASTER HPI Plus 250W/767 BU E40 CRP MASTER HPI Plus 400W/745 BU(-P) (BUS) E40 CRP/SLV MASTER HPI Plus 400W/745 HOR E40 CRP...
Page 26
MASTER HPI Plus Spectral power distribution HPI 400W Performance diagram Lamp performance during run up Lamp performance during run up Lumen maintenance diagram 4000 8000 HPI 250W/400W /743/767 Cap Base Operating position 3.26 OEM Catalogue 2009/2010 [nm] Photometric diagram 240°...
Page 27
MASTER HPI Plus OEM Catalogue 2009/2010 3.27...
Page 28
Warm restart time can be up to fifteen minutes. T15 ignitors are ● therefore advised Dimming only possible with electronic gear, DynaVision 1-10 V ● Achieves optimal performance on Philips PrimaVision electronic ● gear Environment Good environmental choice because of high energy effficiency in ●...
Page 32
Multi-functional lighting for promotional, seasonal and festive ● purposes, at special events etc. Luminaires Must be used in a closed luminaire ● System ArtColour runs on HPI-gear only ● Recommended gear page 3.170 www.philips.com/OEM CNom DNom LMin LNom LMax OMin ONom 43.5 44.5 OMax 45.5...
Page 33
Technical data Type Artcolour MH-T 400W Blue/Green/Violet E40 SLV Light data Type Artcolour MH-T 400W Blue E40 SLV Artcolour MH-T 400W Green E40 SLV Artcolour MH-T 400W Violet E40 SLV Ordering and packing data Type Artcolour MH-T 400W Blue E40 SLV 8711500201591 Artcolour MH-T 400W Green E40 SLV 8711500201638...
Page 34
Artcolour MH-T Lumen maintenance diagram 1000 2000 MH-T 400W BL 1000 2000 MH-T 400W VI 1000 2000 MH-T 400W GR Cap Base Operating position 3.30 OEM Catalogue 2009/2010 3000 4000 5000 Burning hours MH-T 400W GR Life expectancy diagram 3000 4000 5000 Burning hours...
Page 36
MHN-FC lamps require a protective, UV-absorbing front glass and ● correct thermal behaviour for optimal lamp performance Environment This product is RoHS compliant ● This product is covered by WEEE ● Recommended gear page 3.170 www.philips.com/OEM ANom DMax ONom XNom 42.5...
Page 37
MHN-FC 2000W Technical data Type MASTER MHN-FC 1000W/740 230V XW UNP MASTER MHN-FC 2000W/740 400V XW UNP Light data Type MASTER MHN-FC 1000W/740 230V XW UNP MASTER MHN-FC 2000W/740 400V XW UNP Ordering and packing data Type MASTER MHN-FC 1000W/740 230V XW UNP MD-1000/40/2B-H-XW MASTER MHN-FC 2000W/740 400V XW UNP MD-2000/40/2B-H-XW...
Page 38
MASTER MHN-FC Lumen maintenance diagram 2000 4000 MHN-FC 1000W /740/750 Life expectancy diagram 2000 4000 MHN-FC 1000W /740/750 Performance diagram Operating position Lamp performance during run up MHN-FC 3.34 OEM Catalogue 2009/2010 6000 8000 10000 Burning hours MHN-FC 2000W /740 6000 8000 10000...
Page 40
Lowest system energy initially and over lifetime ○ Robust, long-life outdoor-proof installation (lightning strike and ○ peak voltage protection) Environment Philips Green product product with high efficacy minimises ● environmental impact and CO emission: Good environmental choice due to highest energy efficiency in ○...
Page 44
Warm restart time can be up to fifteen minutes. T15 ignitors are ● therefore advised Dimming only possible with electronic gear, DynaVision 1-10 V ● Achieves optimal performance on Philips PrimaVision electronic gear ● Environment Good environmental choice because of high energy effficiency in ●...
Page 45
Technical data Type Current MASTER CityWhite CDO-ET 70W MASTER CityWhite CDO-ET 100W MASTER CityWhite CDO-ET 150W Light data Type MASTER CityWhite CDO-ET 70W/828 E27 SLV MASTER CityWhite CDO-ET 100W/828 E40 SLV MASTER CityWhite CDO-ET 150W/828 E40 SLV Ordering and packing data Type MASTER CityWhite CDO-ET 70W/828 E27 SLV ME-70/28/1B-H-E27...
Page 46
+6/-8% from the voltage indicated on the type plate Warm restart time can be up to fifteen minutes. if the lamp does not ● start (e.g. with T5 ignitors), the installation must be switched off for fifteen minutes Recommended gear page 3.170 www.philips.com/OEM CMax DMax LNom ONom 32.5...
Page 47
Technical data Type Current MASTERColour CDM-TT 70W/942 E27 SLV MASTERColour CDM-TT 150W/942 E40 SLV Light data Type MASTERColour CDM-TT 70W/942 E27 SLV MASTERColour CDM-TT 150W/942 E40 SLV Ordering and packing data Type MASTERColour CDM-TT 70W/942 E27 SLV MT-70/42/1A-H-E27 MASTERColour CDM-TT 150W/942 E40 SLV MT-150/42/1A-H-E40 Spectral power distribution CDM-TT /830...
Page 48
MASTERColour CDM-TT Performance diagram Lamp performance during run up Lamp performance during run up CDM-TT /830 CDM-TT 70W /942 Photometric diagram 210° 180° 150° 240° 120° 240° 1500 1000 500 270° 90° 270° 300° 60° 300° 330° 0° 30° CDM-TT 150W Cap Base 3.48...
Page 50
“Agro” concept with increased blue radiation results in more ● compact and sturdy plant development Ceramic discharge tube with Philips Integrated Antenna (PIA) for a ● long and reliable lifetime ZrAl getter ensures high lumen maintenance and few early failures ●...
Page 51
Technical data Type Lamp Current MASTER Agro 4.13 Light data Type MASTER Agro 400W E40 SLV Ordering and packing data Type ILCOS MASTER Agro 400W E40 SLV ST-400-H/E-E40 Spectral power distribution SON-T Agro 400W Lumen maintenance diagram 8000 16000 SON-T 100W/150W/250W/400W Performance diagram Cap Base Lamp performance during run up...
● maintenance and optimised micromol output Product Features Clear tubular outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a ● long and reliable lifetime ZrAl getter ensures high lumen maintenance and few early failures ● “Green Power” concept with optimised micromol output (growth ●...
Page 53
Technical data Type Current MASTER GreenPower CG T 400W E40 MASTER GreenPower CG T 600W E40 MASTER GreenPower 600W 400V E40 MASTER GreenPower 600W 480V E40 Light data Type MASTER GreenPower CG T 400W E40 SLV/UNP MASTER GreenPower CG T 600W E40 SLV/UNP MASTER GreenPower 600W 400V E40 SLV/UNP MASTER GreenPower 600W 480V E40 SLV Ordering and packing data...
Page 56
● output and long reliable lifetime Product Features Clear tubular outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a ● long and reliable lifetime Robust construction with few welding points is highly vibration- and ● shock-resistant, further reducing early failures and extending lamp...
Page 57
Technical data Type MASTER SON-T PIA Plus 50W/220 E27 SLV MASTER SON-T PIA Plus 70W/220 E27 SLV MASTER SON-T PIA Plus 100W/220 E40 SLV MASTER SON-T PIA Plus 150W/220 E40 SLV MASTER SON-T PIA Plus 250W/220 E40 SLV MASTER SON-T PIA Plus 400W/220 E40 SLV MASTER SON-T PIA Plus 600W/220 E40 SLV Technical data Type...
Page 58
MASTER SON-T PIA Plus Spectral power distribution SON-T Plus 50W/70W E27 SON-T Plus 400W E40 Performance diagram Lamp performance during run up Lamp performance during run up SON-T Plus 50W/70W E27 SON-T Plus 100W/150W/250W E40 Lumen maintenance diagram 8000 16000 SON-T 50W/70W 3.58 OEM Catalogue 2009/2010...
Page 60
Product Features Ovoid, internally white coated outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a ● long and reliable lifetime Robust construction with few welding points is highly vibration- and ●...
Page 61
Technical data Type Current MASTER SON PIA Plus 70W/220 I E27 MASTER SON PIA Plus 100W/220 E40 MASTER SON PIA Plus 150W/220 E40 MASTER SON PIA Plus 250W/220 E40 MASTER SON PIA Plus 400W/220 E40 Light data Type MASTER SON PIA Plus 70W/220 I E27 SLV MASTER SON PIA Plus 100W/220 E40 SLV MASTER SON PIA Plus 150W/220 E40 SLV MASTER SON PIA Plus 250W/220 E40 SLV...
Page 62
MASTER SON PIA Plus Lumen maintenance diagram 8000 16000 SON PIA 50W/70W Life expectancy diagram 8000 16000 SON PIA 50W/70W Operating position 3.62 OEM Catalogue 2009/2010 24000 32000 Burning hours SON PIA 100W/150W/250W/400W 24000 32000 Burning hours SON PIA 100W/150W/250W/400W 8000 16000 24000...
Page 63
MASTER SON PIA Plus OEM Catalogue 2009/2010 3.63...
Page 64
● reliable lifetime and no Mercury Product Features Clear tubular outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a ● long and reliable lifetime Robust construction with few welding points is highly vibration- and ● shock-resistant, further reducing early failures and extending lamp...
Page 65
Technical data Type MASTER SON-T PIA Hg-Free 100W/221 E40 SLV MASTER SON-T PIA Hg-Free 150W/221 E40 SLV MASTER SON-T PIA Hg-Free 250W/221 E40 SLV MASTER SON-T PIA Hg-Free 400W/221 E40 SLV Technical data Type MASTER SON-T PIA Hg-Free 100W/221 E40 SLV MASTER SON-T PIA Hg-Free 150W/221 E40 SLV MASTER SON-T PIA Hg-Free 250W/221 E40 SLV MASTER SON-T PIA Hg-Free 400W/221 E40 SLV...
Page 66
MASTER SON-T PIA Hg-Free Performance diagram Lamp performance during run up Lamp performance during run up SON-T Hg Free 100W/150W/250W SON-T Hg Free 400W E40 Lumen maintenance diagram 8000 16000 SON-T 100W/150W/250W/400W Photometric diagram 210° 180° 150° 240° 120° 240° 270°...
Page 67
MASTER SON-T PIA Hg-Free OEM Catalogue 2009/2010 3.67...
Page 68
Mercury Product Features Ovoid, internally white coated outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a ● long and reliable lifetime Robust construction with few welding points is highly vibration- and ●...
Page 69
Technical data Type Current MASTER SON PIA 50W/220 E27 SLV MASTER SON PIA 70W/220 E27 SLV MASTER SON PIA Hg Free 150W/221 E40 SLV MASTER SON PIA Hg Free 250W/221 E40 SLV MASTER SON PIA Hg Free 400W/221 E40 SLV Light data Type MASTER SON PIA 50W/220 E27 SLV...
Page 70
MASTER SON PIA (Hg-Free) Lumen maintenance diagram 8000 16000 SON PIA 50W/70W Life expectancy diagram 8000 16000 SON PIA 50W/70W Photometric diagram 210° 180° 150° 240° 120° 240° 270° 90° 270° 300° 60° 300° 330° 0° 30° SON PIA Cap Base 3.70 OEM Catalogue 2009/2010 24000...
Page 71
MASTER SON PIA (Hg-Free) OEM Catalogue 2009/2010 3.71...
Page 72
Sodium, offering good value for money Technical Features High Pressure Sodium lamp with clear outer bulb ● Clear tubular outer bulb ● Robust construction is vibration- and shock-resistant leading to a ● reliable life Dimming possible with dedicated gear ● Recommended gear page 3.170 www.philips.com/OEM...
Page 74
Robust construction is vibration- and shock-resistant leading to a ● reliable life Dimming possible with dedicated gear ● Require a ballast and ignitor, except for SON 70W I lamps which ● have an internal ignitor Recommended gear page 3.170 www.philips.com/OEM...
Page 75
Preferred selection Product ID SON 70W SON 70W SON 150W SON 250W SON 400W Product ID SON 70W SON 70W SON 150W SON 250W SON 400W Product ID Wattage EM SON 70W SON 70W SON 150W SON 250W SON 400W Ignitor Cap/ Base Packing...
Page 76
The ideal balance between colour impression and energy efficacy ● Application City centres and residential areas ● Decorative floodlighting ● Commercial and industrial applications ● Recreational sports facilities indoor and outdoor ● Recommended gear page 3.170 www.philips.com/OEM CMax DMax LNom ONom...
Page 77
Technical data Type Current SON-T Comfort 150W SON-T Comfort 250W SON-T Comfort 400W Light data Type SON-T Comfort 150W/621 E40 SLV SON-T Comfort 250W/621 E40 SLV SON-T Comfort 400W/621 E40 SLV Ordering and packing data Type SON-T Comfort 150W/621 E40 SLV STM-150-H/E-E40 SON-T Comfort 250W/621 E40 SLV STM-250-H/E-E40...
Page 78
The ideal balance between colour impression and energy efficacy ● Application City centres and residential areas ● Commercial and industrial applications ● Recommended gear page 3.170 www.philips.com/OEM Type SON Comfort 150W/250W/621 E40 SLV SON Comfort 400W/621 E40 SLV CMax DMax 121.5...
Page 79
Technical data Type Current SON Comfort 150W/621 E40 SLV SON Comfort 250W/621 E40 SLV SON Comfort 400W/621 E40 SLV Light data Type SON Comfort 150W/621 E40 SLV SON Comfort 250W/621 E40 SLV SON Comfort 400W/621 E40 SLV Ordering and packing data Type ILCOS SON Comfort 150W/621 E40 SLV...
Page 80
Commercial and industrial applications ● System Require an HPL gear without ignitor ● Recommended gear page 3.170 www.philips.com/OEM Type SON H 68W/220 E27 SLV SON H 110W/220 E27 SLV SON H 220W/220 E40 SLV SON H 350W/220 E40 SLV CMax DMax 164.4...
Page 81
Technical data Type SON H 68W/220 E27 SLV SON H 110W/220 E27 SLV SON H 220W/220 E40 SLV SON H 350W/220 E40 SLV Light data Type SON H 68W/220 E27 SLV SON H 110W/220 E27 SLV SON H 220W/220 E40 SLV SON H 350W/220 E40 SLV Ordering and packing data Type...
Page 82
SON H Lumen maintenance diagram 4000 8000 12000 16000 SON H 110W Life expectancy diagram 4000 8000 12000 16000 SON H 110W Cap Base 3.82 OEM Catalogue 2009/2010 20000 24000 28000 32000 Burning hours SON H 220W/350W 20000 24000 28000 32000 Burning hours SON H 220W/350W...
Page 98
● Combines a continuous spectrum from the incandescent source and ● a line spectrum from the high-pressure mercury source It is recommended to protect ML against water splashes ● ML lamps are not dimmable ● Recommended gear page 3.170 www.philips.com/OEM...
Page 99
Burning position Universal ML 100 W ML 160 W Preferred selection Product ID ML100W ML160W ML160W ML250W ML250W ML250W ML500W Product ID ML100W 220-230V ML160W 220-230V ML160W 220-230V ML250W 225-235V ML250W 220-230V ML250W 220-230V ML500W 220-230V ML500W 225-235V Burning position Burning position ML 250 W ML 500 W lamp...
Page 101
The Philips HID electronic gear range was designed for total compatibility with Philips HID lamps. Philips is leader in the field of electronic technology and we have applied this knowledge to our developments of control gear for lighting products. Each lamp and gear combination requires extensive life testing before being released as a complete system.
Page 103
These types can be recognised by the TS indication. For the whole range of lamps, a full range of electronic ignitors is offered. Philips prefers and advice customers to use the so-called by Philips developed semi-parallel ignitors (also called impulser type).
Page 104
Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electronic control ● gear, Philips ensures that, from the earliest development stage, optimum lamp/driver performance is maintained. European standards: Philips HID electronic drivers comply with all ●...
Page 105
Type HID-PrimaVision SON/CDO HID-PV Inrush current Type HID-P 70 /S SON/CDO 220-240V 50/60Hz HID-P 100/150 /S SON/CDO 220-240V 50/60Hz Electrical data Type Number Lamps HID-P 70 /S SON/CDO 220-240V HID-P 100 /S SON/CDO 220-240V HID-P 150 /S SON/CDO 220-240V Ordering and packing data Type HID-P 70 /S SON/CDO 220-240V 50/60Hz HID-P 100 /S SON/CDO 220-240V 50/60Hz...
Page 106
HID-PrimaVision SON and CDO Electrical installation notes Mains operation Rated mains voltage 220 - 240 V With tolerances for performance 203 - 254 V +6%-8 With tolerances for operation 180 - 264 V Mains frequency 50/60 Hz Power factor > 0.98 Earth leakage current <...
Page 107
HID-PrimaVision SON and CDO OEM Catalogue 2009/2010 3.107...
Page 108
Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electronic control ● gear, Philips ensures that, from the earliest development stage, optimum lamp/driver performance is maintained. European standards: Philips HID electronic drivers comply with all ●...
Page 109
Type HID-DynaVision 1-10V SON/CDO HID-DV Inrush current Type HID-D 1-10V 100/150 SON/CDO HID-D 1-10V 70 SON/CDO Electrical data Type Number Lamps HID-D 1-10V 100 /S CDO 220-240V HID-D 1-10V 100 /S SON 220-240V HID-D 1-10V 150 /S CDO 220-240V HID-D 1-10V 150 /S SON 220-240V HID-D 1-10V 70 /S CDO 220-240V HID-D 1-10V 70 /S SON 220-240V Ordering and packing data...
Page 110
HID-DynaVision SON and CDO Notes: 1. With three-phase mains supply, neutral should never be disconnected; otherwise circuitry could be damaged. 2. For proper EMC, wiring inside luminaire should be as straight and as short as possible; mains wires should not run parallel to lamp wires. 3.
Page 111
HID-DynaVision SON and CDO OEM Catalogue 2009/2010 3.111...
Page 112
Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electronic control ● gear, Philips ensures that, from the earliest development stage, optimum lamp/driver performance is maintained. European standards: Philips HID electronic drivers comply with all ●...
Page 113
Type HID-DynaVision DALI HID-DV Inrush current Type HID-D DALI 100-150 /S CDO/SON/SDW Electrical data Type HID-D DALI 100-150 /S CDO/SON/SDW Ordering and packing data Type HID-D DALI 100-150 /S CDO/SON/SDW Electrical installation notes Mains operation Rated mains voltage 220-240 V With tolerances for performance 203-254 V +6%-8%...
Page 114
HID-DynaVision DALI SON and CDO Control characteristics Control input DALI Input is protected against mains voltage connection Dimming fading rates are implemented to guarantee optimal lamp Behaviour for SON Lamps: Run up time before dimming* 5 minutes Fade down time** (100%-20%) <...
Page 115
HID-DynaVision DALI SON and CDO OEM Catalogue 2009/2010 3.115...
Page 116
Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electronic control ● gear, Philips ensures that, from the earliest development stage, optimum lamp/driver performance is maintained. European standards: Philips HID electronic drivers comply with all ●...
Page 117
Type EXC 35/36/55/66 SOX(-E) EXC 91 SOX-E Inrush current Type EXC 35/36 SOX(-E) EXC 55/66 SOX(-E) EXC 91 SOX-E Electrical data Type Number Lamps EXC 35 SOX 220-240V 50/60Hz EXC 36 SOX-E 220-240V 50/60Hz EXC 55 SOX 220-240V 50/60Hz EXC 66 SOX-E 220-240V 50/60Hz EXC 91 SOX-E 220-240V 50/60Hz Ordering and packing data Type...
Page 118
Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electronic control ● gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained European standards: Philips HID electronic gears comply with all ●...
Page 119
Type HID-PrimaVision Xtreme 45/60 /S CPO-TW HID-PrimaVision Xtreme 90/140 /S CPO-TW HID-PV Xt Inrush current Type HID-PrimaVision Xtreme 45/60 /S CPO-TW 220-240V 50/60Hz HID-PrimaVision Xtreme 90/140 /S CPO-TW 220-240V 50/60Hz Electrical data Type Number HID-PXt 45 /S CPO-TW 220-240V HID-PXt 60 /S CPO-TW 220-240V HID-PXt 90 /S CPO-TW 220-240V HID-PXt 140 /S CPO-TW 220-240V Ordering and packing data...
Page 120
Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electronic control ● gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained European standards: Philips HID electronic gears comply with all ●...
Page 121
Type HID-DLS Xt 60 CPO-TW HID-DV Inrush current Type HID-DLS Xt 60 CPO-TW Electrical data Type Number Rated Gear- Lamps Lamp Power HID-DLS Ordering and packing data Type HID-DLS-6 Xt 60 /S CPO-TW 220-240V HID-DLS-8 Xt 60 /S CPO-TW 220-240V HID-DLS-10 Xt 60 /S CPO-TW 220-240V HID-DV A1Nom...
Page 122
Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electronic control ● gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electronic gears comply with all ●...
Page 123
Ordering and packing data Type HID-DVC 250 SON 220-240V 50/60Hz BSH 250/400 L36 220/240V 50/60Hz HD1-118 HID-DVC 400 SON 220-240V 50/60Hz Approval marking CE-marking Environmental standard Recommended lamp page 3.170 www.philips.com/OEM Inrush Inrush current current Peak Width (ms) 0.10 Number...
Page 124
HID-DynaVision Control SON Electrical installation notes Mains operation Rated mains voltage 220 - 240 V With tolerances for performance 203 - 254 V With tolerances for operation 180 - 264 V Mains frequency 50/60 Hz Operation frequency (typical) 50 Hz Power factor* (nominal power) >...
Page 125
HID-DynaVision Control SON OEM Catalogue 2009/2010 3.125...
Page 126
Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electronic control ● gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electronic gears comply with all ●...
Page 127
Electrical data Type SDU-01/H /L Ordering and packing data Type SDU-01/H SDU-01/L Electrical installation notes Mains operation With tolerances for performance 220 - 240 V -8%…+6% Control voltage 198 - 260 V Max input current 160 mA Number Rated Line Gear- Frequency Lamps...
Page 128
Quality Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electromagnetic ● control gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electromagnetic gears comply with ●...
Page 129
Type BMH 35/70 BSN 50 BSN 100 BSN 150 BSN 250 BMH/BSN Type BSN 400/600 Electrical data Type Number Lamps BMH35L407ITS BMH70L407ITS BSN50L407ITS BSN70L407ITS BSN100L302I BSN100L407ITS BSN150L407I BSN150L407ITS BSN250L407I BSN250L407ITS BSN400L302I BSN400L407ITS BSN600L407ITS BSN600L309ITS A1Nom 166.0 Rated Power Line Gear- losses Frequency Lamp...
Page 130
HID-Basic BSN/BMH semi-parallel ignitor Ordering and packing data Type BMH35L407ITS BMH70L407ITS BSN50L407ITS BSN70L407ITS BSN100L302I BSN100L407ITS BSN150L407I BSN150L407ITS BSN250L407I BSN250L407ITS BSN400L302I BSN400L407ITS BSN600L407ITS BSN600L309ITS Electrical installation notes Mains operation With tolerances for performance -8% / +6% With tolerances for operation -10% / +10% Operation frequency (typical) 50 Hz Power factor with specified...
Page 132
Quality Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electromagnetic ● control gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electromagnetic gears comply with ●...
Page 133
Type BSN 50/70 BSN 70/100 BSN 100/150 Type BSN 150/250 & 250/400 Electrical data Type Number BSN 50/70 L407-TS 230/240V 50Hz BSN 70/100 L407-TS 230/240V 50Hz BSN 100/150 L407-TS 230/240V 50Hz BSN 150/250 L407-TS 230/240V 50Hz BSN 250/400 L407-TS 230/240V 50Hz Ordering and packing data Type BSN 50/70 L407-TS 230/240V 50Hz...
Page 134
Quality Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electromagnetic ● control gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electromagnetic gears comply with ●...
Page 138
Quality Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electromagnetic ● control gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electromagnetic gears comply with ●...
Page 139
Type BHL 50 BHL 80 BHL 125 L202/L307 BHL 250 L200/L202 BHL 250 L307 BHL 400 L200/L202 BHL 400 L307 Electrical data Type BHL50L307 BHL80L307 BHL125L202 BHL125L307 BHL250L200 BHL250L202 BHL250L307 BHL400L200 BHL400L202 BHL400L307 A1Nom Number Rated Power Line Gear- losses Frequency Lamps Lamp...
Page 140
HID-Basic BHL (HPL/HPI) Ordering and packing data Type BHL50L307 BHL80L307 BHL125L202 BHL125L307 BHL250L200 BHL250L202 BHL250L307 BHL400L200 BHL400L202 BHL400L307 Electrical installation notes Mains operation With tolerances for performance -8% / +6% With tolerances for operation -10% / +10% Operation frequency (typical) 50 Hz Power factor with specified 0.85...
Page 142
Quality Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electromagnetic ● control gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electromagnetic gears comply with ●...
Page 146
Quality Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electromagnetic ● control gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electromagnetic gears comply with ●...
Page 150
Quality Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electromagnetic ● control gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electromagnetic gears comply with ●...
Page 151
Type BSX 26/35 + 35/55 Electrical data Type Number BSX 26 L80 220V 50Hz BSX 26 L81 230V 50Hz BSX 26 L82 240V 50Hz BSX 35 L80 220V 50Hz BSX 35 L81 230V 50Hz BSX 35/55 L204 240V 50Hz BSX 35/55 L82 240V 50Hz Ordering and packing data Type BSX 26 L80 220V 50Hz...
Page 152
Quality Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electromagnetic ● control gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electromagnetic gears comply with ●...
Page 153
Type HID-HeavyDuty BSX 50Hz HD1-118 Electrical data Type BSX 35 L40 230V 50Hz BSX 35/55 L32 240V 50Hz BSX 90 L32 240V 50Hz BSX 90 L40 230V 50Hz Ordering and packing data Type BSX 35 L40 230V 50Hz BSX 35/55 L32 240V 50Hz BSX 90 L32 240V 50Hz BSX 90 L40 230V 50Hz Electrical installation notes...
Page 154
Quality Philips Quality assures optimum quality regarding: System supplier: As manufacturers of lamps and electromagnetic ● control gear, Philips ensures that, from the earliest development stage, optimum lamp/gear performance is maintained. European standards: Philips HID electromagnetic gears comply with ●...
Page 156
Compliances and approvals Safety EN 60922 ● Perfonmance EN 60923 ● Quality standard ISO 9001 ● Environmental standard ISO 14001 ● CE Marking ● Recommended lamp page 3.170 www.philips.com/OEM, 51.5 57.1 51.5 57.1 64.5 75.5 64.5 75.5 82.0 96.5...
Page 157
Data valid for typical lamps Ballast For lamps Ignitor Vol./Freq. BSN70L3001 SON 70W SN57 BSN70L300ITS SON 70W SN57 BSN70L301I SON 70W SN57 BSN70L302I SON 70W SN57 BSN70L304I SON 70W SN57 BSN100L300I SON 100W SN58(T5) BSN100L301I SON 100W SN58(T5) BSN100L302I SON 100W SN58(T5) BSN100L304I SON 100W...
Page 158
HID-Basic ballasts for SON and HPI (plus) lamps with Semi-parallel ignitor Marking “designed by Philips Lighting B.V. , the Netherlands” Ordering and packing data Type Weight BSN70L300I BSN100L300I BSN150L300I 1.85 BSN250L300I BSN400L300I BSN70L301I BSN100L301I BSN150L301I 1.85 BSN150L301ITS 1.85 BSN250L301I BSN400L301I 4.45...
Page 159
Marking “Made in China” Ordering and packing data Type Weight BSN70L300I BSN100L300I BSN150L300I 1.85 BSN250L300I BSN400L300I BSN70L301I BSN100L301I BSN150L301I 1.85 BSN150L301ITS 1.85 BSN250L301I BSN400L301I 4.45 BSN100L302I BSN150L302I 1.85 BSN150L302ITS 1.85 BSN250L302I BSN400L302I BSN1000L302I BSN70L304I BSN100L304I BSN150L304I 1.85 BSN150L304ITS 1.85 BSN250L304I BSN400L304I For full information on ignitors mentioned, please refer to separate product data sheet.
Page 160
● relative humidity is limited. Compliances and approvals Safety EN 60922 ● Perfonmance EN 60923 ● Quality standard ISO 900I ● Environmental standard ISO 14001 ● CE Marking, ● Recommended lamp page 3.170 www.philips.com/OEM 51.5 57.1 64.5 75.5 64.5 75.5...
Page 164
Harmonic current emissions EN 61000-3-2 EMC immunity EN 61547 Approval marking ENEC CE-marking Environmental standard ISO 14001 Recommended lamp page 3.170 www.philips.com/OEM Type A1Nom SU 10-S \ SU 40-S 78.0 SUD 10-S \ SU 40-S 78.0 A3Nom B1Nom C1Nom 62.0 36.0...
Page 165
Type SI 51 / SI 52 / SN 57 / SN 57T5 / SN 57T15 / SND 57 / SN 58 / SN 58T5 / SN 58T15 / SND 58 SX 131 Type SND 57-S / SN 57T15-S / SI 51-S / SN 57-S Type SN 56 / SI 54 / SN 61 / SX 26 / SND 88 SND 88/89...
Page 166
HID ignitors Electrical data Type Number Rated Gear- Lamps Lamp Power SI 51 220-240V 250/400 SI 51-S 220-240V 1000 SI 52 220-240V 250/400 SI 54 360-415V 2000 SN 56 220-240V 1000/1800 SN 57 220-240V 50/70 SN 58 220-240V 35-400 SN 59 220-240V 1000/1800 SND 57-S 220-240V 50/70...
Page 167
Ordering and packing data Type EAN code SI 51 220-240V 50/60Hz 8711500915535 SI 51-S 220-240V 50/60Hz 8711500747495 SI 52 220-240V 50/60Hz 8711500915542 SI 54 360-415V 50/60Hz 8711500915481 SN 56 220-240V 50/60Hz 8711500915603 SN 57 220-240V 50/60Hz 8711500915559 SN 57-S 220-240V 50/60Hz 8711500060525 SN 58 220-240V 50/60Hz 8711500915566...
Page 168
HID ignitors SI 52 SU/SUD SX 131/73 3.168 OEM Catalogue 2009/2010 SN 50/56/57/57-S/58/58-S/59 SX 70/72/74/76 SN 61 SI 51/51-S/54...