Safety Related Adjustments; Confirmation When Replacing H.v.r. - Sony PVM-1444QM Service Manual

Trinitron color video monitor
Table of Contents

Advertisement

PVM-1 440QM/1 442QM/1
444QM
SECTION
4
SAFETY RELATED ADJUSTMENTS
CONFIRMATION
WHEN
REPLACING
H.V.R
(High
Voltage
Resistor)
The
following
adjustment should
be confirm
the
output
voltage
when
replacing
HVR.
1.
Receive an
entire
white
signal.
2.
CONTRAST
Maximum
BRIGHTNESS
Maximum
3.
Connect
a digital
multimeter
to the
A-20
connector
side lead of
R804.
4.
Confirm
the voltage
is
14.1
±1.0
V
DC.
$KR500.
CONFIRMATION
METHOD (HOLDDOWN
CONFIRMATION)
AND READJUSTMENTS
The
following
adjustments should always
be
performed
when
replacing the following
components.
IC501
,
Q503, Q504, Q505, Q506,
D509, D51
0.
C505, C520, C524,
C525, C526. C527, C528, C529,
C530,
C531
,
R500, R506, R516,
on
A
board
R51
7,
R51
8,
R519, R520. R521,
R522, R523, R524. R525, R526,
R528, R804,
NL501,
HVR
1.
Receive an
entire
white
signal.
2.
CONTRAST
Maximum
BRIGHTNESS
Maximum
3.
Connect
a digital
multimeter
to the
A-20
connector
side lead
of
R804.
4.
Confirm
the voltage
is
14.1
±1.0
V
DC.
5.
Receive
a
dot
signal.
6.
Disconnect
A-22
connector
(ABL
JIG)
on
A
board
and connect an ammeter.
7.
Adjust
BRIGHTNESS
and
CONTRAST
so
that
the
current
is
70
±30
u
A.
8.
Apply
an
external
DC
voltage gradually to the A-
2Q
connector
side
lead
of
R804,
and
when
the
voltage
becomes
16.4
±0.1
V
DC, confirm
the
HOLD-DOWN
circuit
operates
immediately
and
raster
disappears.
9.
With
the
same
procedure
of
item
8,
when
the
voltage
becomes
15.8
±0.1
V
DC, confirm
the
HOLD-DOWN
circuit
doesn't
operate.
10.
Receive an
entire
white
signal.
11.
Adjust with
BRIGHTNESS
and
CONTRAST
volumes
so
that
the current
is
600
±40
u
A.
12.
Apply
DC
voltage
to
the
A-20
connector
side lead
of
R804, and
when
the voltage
becomes
15.8 ±0.1
V
DC, confirm
the
HOLD-DOWN
circuit
operates
immediately
and
raster
disappears.
13.
With
the
same
procedure
of
item
8,
when
the
voltage
becomes
15.2
±0.1
V
DC, confirm
the
HOLD-DOWN
circuit
doesn't
operate.
14.
When
step
4
to
1
3
is
not
satisfied,
readjustment
should
be
performed by
altering
the resistance
value
of
R500
0§9.
i
-