3-9. Return Video Level Adjustment
BOARD
Encoder
SPEC.
A = 1.0V ± 20mV
TEST
VIDEO OUT
ADJUST
VR403
MODE
Video In : Colour Bar
M.EQ
Oscilloscope, Waveform Monitor,
EVR, Signal Generator
1. Mounting the VIDEO IN connector (Accessory).
See operating instruction page 17.
2. Input the colour bar signal to VIDEO IN connector.
3. Confirm that the EVR display indicates [1E][02][00]
and then press the [→] to set the EVR to
[1E][03][00]. Otherwise press the [CMD][1E]
[DATA][03] [ADR][00] [SET] to input [1E][03][00].
4. Connect the Waveform Monitor with VIDEO OUT
and adjust the VR403 so that the level A is within
specification.
3-10. Mon Enc Level Adjustment
BOARD
SPEC.
TEST
ADJUST
MODE
M.EQ
1. Confirm that the EVR display indicates [1E][03][00]
and then press the [→] to set the EVR to
[1E][04][00]. Otherwise press the [CMD][1E]
[DATA][04] [ADR][00] [SET] to input [1E][04][00].
2. Connect the Waveform Monitor with VIDEO OUT
and adjust the VR401 so that the level A is within
specification.
A
Encoder
A = 1.0V ± 20mV
VIDEO OUT
VR401
Camera Bar
Oscilloscope, Waveform Monitor, EVR
A