Environmental Type Tests - Siemens RUGGEDCOM i803 Installation Manual

Hide thumbs Also See for RUGGEDCOM i803:
Table of Contents

Advertisement

Chapter 6
Certification
IEEE 1613 EMC Immunity Type Tests
ESD
Radiated RFI
Fast Transient
Oscillatory

Environmental Type Tests

Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-6
IEC 60068-2-27
28
Description
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
Earth ground ports
Signal ports
DC Power ports
Cold Temperature
Dry Heat
Humidity (Damp Heat, Cyclic)
Vibration
Shock
2.5 kV common mode @ 1MHz
2.5 kV common, 1 kV differential mode @ 1MHz
Description
Test Ad
Test Bd
Test Db
RUGGEDCOM i803
Installation Guide
Test Levels
± 8 kV
± 8 kV
35 V/m
± 4 kV @ 5 kHz
± 4 kV @ 5 kHz
± 4 kV @ 5 kHz
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
1 g @ 10-500 Hz
30 g @ 11 ms
EMC and Environmental Type Tests

Advertisement

Table of Contents
loading

Table of Contents