Chapter 4. Specifications

4.3.2 Clamp-On Transducers

Temperature Range:
Standard: –40° to 300°F (–40° to 150°C)
Optional (overall range): -310
Mounting:
Stainless steel chain or strap, welded or magnetic clamping fixtures
Area Classifications:
Standard: General-purpose
Optional:
Explosion proof: Class I, Div. 1, Groups B, C & D; Class II, Groups E, F and G; Class III
Flameproof:
II 2 G EEx md IIC T6-T3
Weatherproof: Type 4/IP65
Submersible
Note: Clamp-on transducers for special applications and flowcells are also available. Consult the factory for details.

4.3.3 Transducer Cables

Length:
Standard: Pair of coaxial cables, type RG62 aU, length to 3 ft (1 m)
Optional: Lengths up to 1000 ft (330 m) maximum

4.3.4 Temperature Transducers (optional)

Type:
Loop-powered 3-wire platinum RTDs; clamp-on and wetted (thermowell) types are available
Range:
o
o
o
-4
F to 500
F (-20
C to 260
Accuracy:
o
o
0.27
F (0.15
C), wetted RTDs, matched pairs
64
o
o
o
to 572
F (-190
to 300
o
C), not all extremes of parameters can be achieved simultaneously
o
C)