HTR-2064/NS-B20/NS-C20/NS-SWP20
2-2. When the protection function worked due to a short between speaker terminals.
Cause: The line between speaker terminals is shorted.
Supplementary information: As the excess current is detected after operation of the speaker relay, the shorted speaker
terminal and the connected speaker can be identified.
Turning on the power without correcting the abnormality will cause the protection function to work immediately and the
power supply will instantly be shut off.

2-3. When the protection function worked due to abnormal DC output.

Cause: DC output of the power amplifier is abnormal.
Supplementary information: The protection function worked due to a DC voltage appearing at the speaker terminal. A
cause could be a defect in the amplifier.
Turning on the power without correcting the abnormality will cause the protection function to work in 3 seconds and the
power supply will be shut off.
2-4. When the protection function worked due to abnormal voltage in the power supply section.
Cause: The voltage in the power supply section is abnormal.
Supplementary information: The protection function worked due to a defect or overload in the power supply.
Turning on the power without correcting the abnormality will cause the protection function to work in 1 seconds and the
power supply will be shut off.
2-5. When the protection function worked due to excessive heatsink temperature.
Cause: The temperature of the heatsink is excessive.
Supplementary information: The protection function worked due to the temperature limit being exceeded.
Causes could be poor ventilation or a defect related to the thermal sensor.
Turning on the power without correcting the abnormality will cause the protection function to work in 1 seconds and the
power supply will be shut off.
*
For detection of each protection function, refer to main menu described later.
● History of protection function
When the protection function has worked, its history is stored in memory as backup data.
Even if no abnormality is noted while servicing this unit, an abnormality which has occurred previously can be defined
as long as the backup data has been stored.
The history of the protection function will be initialized when self-diagnostic function is cancelled with "24-2. PRESET
RESERVED" (Memory initialized) menu selected.
28
I P R O T E C T
D C P R T : x x x H
AD value when the protection function is working
P S P R T : x x x L
AD value when the protection function is working
T M P P R T : x x x L
AD value when the protection function is working

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Htr-2064Ns-b20Ns-c20Ns-swp20

Table of Contents