Sony SLV-SE850 Service Manual page 6

Table of Contents

Advertisement

2. EEPROM DATA INPUT
When EEPROM (IC182 on FR-169 board) is replaced with new one or "888" appears for short time on CH indicator after AC plug OFF/ON,
perform the following procedure.
Fluorescent display tube
1) Connect the adjustment remote commander (RM-95: J-6082-053-B) with CN165 of MA-388 board by using LANC jig (J-6082-051-A).
2) Select page: 1, address: 00, and input data: 80.
3) Select page: F, and input data as following table.
Page
Address
02
0A
0B
SLV-SE850B
01
95
CE
SLV-SE850D
00
85
CE
SLV-SE850E
02
85
CE
SLV-SE850G
03
85
CE
SLV-SF900B
06
95
CE
SLV-SF900D
05
85
CE
SLV-SF900E
07
85
CE
SLV-SF900G
08
85
CE
SLV-SF950N
0F
A5
CE
SLV-SF990B
0B
95
CE
SLV-SF990D
0A
85
CE
SLV-SF990E
0C
85
CE
SLV-SF990G
0D
85
CE
Note: Press the PAUSE button of the adjustment remote commander each time to set the data.
4) Turn off the power to reset.
5) Perform "RF Switching Position Adjustment" and "AF Switching Position Adjustment".
6) Make sure whether the function of the set works normally.
8 88
F
0C
0D
B4
BA
BB
BC
20
00
25
04
8C
A0
20
01
20
04
8C
20
20
01
20
04
8C
A0
20
01
15
04
88
A0
20
00
25
04
8C
A0
20
01
20
04
8C
20
20
01
20
04
8C
A0
20
01
15
04
88
A0
20
03
20
04
8C
20
20
02
25
04
8C
A0
20
03
20
04
8C
20
20
03
20
04
8C
A0
20
03
15
04
88
A0
— 6 —
BD
00
00
00
00
00
00
00
00
00
00
00
00
00

Hide quick links: