3.5.8. Charging
Charging block in ABB processes charging operation by using VBAT, ICHG value through ADC
channel. Battery Block Indication and SPEC of CG225 is as follow.
4.2V~3.87V
1. Charging method: CC-CV
2. Charger detect voltage: about 5.2V
3. Charging time: 3h under
4. Icon stop current: 120mA
5. Charging current: 550mA
6. CV voltage: 4.2V
7. Cutoff current: 30mA
8. Full charge indication current (icon stop current) : 100mA
9. Recharge voltage: 4.16V
10. Low battery alarm
a. Idle: 3.55V
b. Dedicated: 3.59V
11. Low battery alarm interval :
a. Idle: 2min
b. Dedicated:1min
12. Power-off voltage without TA : 3.35V
Power-off voltage with TA : 2.80V
13. Charging temperature ADC range
a. ~ -5°C : small charging operation.
b. -5°C ~ 50°C : charging.
c. 50°C ~ : small charging operation.
3.86V~3.75V