Download Print this page

Honeywell TH9421C1004 Installation Manual page 3

Visionpro iaq
Hide thumbs Also See for TH9421C1004:

Advertisement

Available languages

Available languages

Installer setup
Setup function
0210
External fossil
fuel kit
0220
Stage 1 compressor
1cycle rate
0230
Stage 2 compressor
cycle rate
0240
Stage 1 heat cycle
rate (CPH= cycles
per hour)
0250
Stage 2 stage heat
cycle rate (CPH)
0260
Stage 3 heat cycle
rate (CPH)
0280
Backlight
0300
Manual/Auto
changeover
0310
Auto changeover
deadband
0320
Temperature display 0
0330
Daylight savings
0340
Indoor temp.
sensor
0342
Outdoor temp.
sensor
0345
Dual fuel heat
pump control
0346
Dual fuel heat
pump upstage to
furnace timer
0350
Heat pump
compressor lockout
0360
Heat pump
auxiliary lockout
0365
Discharge temp.
sensor
0370
Indoor humidity
sensor
Settings & options (factory default in bold)
1
External fossil fuel kit controls backup heat
0
Thermostat controls backup heat (outdoor sensor required)
E
Auto Discover
[Other options: 1 to CPH]
E
Auto Discover
[Other options: 1 to 6 CPH]
E
Auto Discover
[Other options: 1 to 12 CPH]
E
Auto Discover
[Other options: 1 to 12 CPH]
E
Auto Discover
[Other options: 1 to 12 CPH]
0
Backlight on for approx. 45 seconds after keypress
1
Backlight always on low intensity, full bright after keypress
0
Manual (User options: Heat/Cool/Off)
1
Automatic (User options: Heat/Cool/Auto/Off)
(System selects heat/cool based on indoor temp.)
3
Heat/cool settings 3°F apart (1.5°C)
[Other options: 2-9 (2°F to 9°F/1°C to 5°C)]
Fahrenheit
1
Celsius
2
Auto-change to daylight savings time (2007 and beyond, for
areas that use the new 2007 DST calendar)
1
Auto-change to daylight savings time (through 2006, and for areas
that do not use the new 2007 DST calendar)
0
Daylight savings time is turned off
0
Display temp. at thermostat location only
1
Display temp. at indoor sensor location(s)
2
Average between thermostat & sensor location(s)
E
Auto Discover
0
None
1
Remote sensor
1
Balance point plus 2°F droop
0
Balance point only
2
Balance point/Aux Heat Lockout plus 2°F droop
**
60
60 minutes
0
Off
[Other options: 30, 45 or 75 minutes]
0
No compressor lockout
[Other options: 5 to 60°F (-15°C to 15.5°C)]
0
No heat pump auxiliary lockout
[Other options: 5 to 65°F (-15°C to 18.5°C)]
E
Auto Discover
0
No
1
Yes
1
Internal sensor in thermostat
0
Sensors disabled
E
Auto Discover
**
3
**
**
**
**
**
**
**
**
**
**
**
VisionPRO® IAQ
**
**See page 6
69-1816EFS—03

Advertisement

loading