MECHANICAL ADJUSTMENT
BASIC NEEDLE POSITION
* IF THE LEFT NEEDLE POSITION IN MAXIMUM ZIGZAG AND IN STRAIGHT
SEWING
ARE NOT THE SAME, ADJUST AS FOLLOWS:
ADJUSTMENT
PROCEDURE:
1.
REMOVE THE BELT COVER (SEE P.8).
2.
SELECT THE LEFT NEEDLE POSITION IN MAXIMUM ZIG ZAG, THEN SELECT THE LEFT
NEEDLE POSITION IN STRAIGHT SEWING.
3.
IF THE RESULT LOOKS LIKE (A) SEE BELOW, TURN THE ADJUSTING
SCREW IN
DIRECTION (D).
IF THE RESULT LOOKS LIKE (B) SEE BELOW, TURN THE ADJUSTING
SCREW IN
DIRECTION (C).
4.
REPLACE THE BELT COVER (SEE P.8).
ADJUSTING
SCRE___r_
_
NEEDLE POSITION IN
MAXIMUM ZIGZAG
NEEDLE POSITION IN
STRAIGHT SEWING
i
i
i
i
(B)
CORRECT
INCORRECT
INCORRECT