Principle of the STARTER commissioning tool for SINAMICS S120

When you create a drive unit for a SINAMICS S120 system, the following principles
apply:
The tool is used to configure objects (e.g. infeed). The object name is user defined.
In STARTER, a drive unit always comprises a Control Unit and the associated
drives.
With a controlled infeed, the Active Line Module is configured in STARTER. An
uncontrolled infeed is not configured in STARTER.
The appropriate drive consists, for example, of a Motor Module (power section)
and of a motor with encoder.
Fig. 2-4 shows the STARTER project navigator. You can see that a project
(Project_Philosophy) and a drive unit (Drive_Unit_One_Motor) have been con-
figured for a drive.
Fig. 2-4
2-26
Drive unit with one motor
SINAMICS S120 Getting Started with the STARTER Commissioning Tool – 03/2006 Edition