CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confi rm that focus bias.
FOCUS BIAS CHECK
1. Connect the oscilloscope between IC701 pin 2 and pin qa (or
TP (RF OUT) and TP (VC)).
2. Insert the disc (PATD-012 (Tr 15)). (Part No. : 4-225-203-01)
3. Press the [
] (CD) button.
N X
4. Confi rm that the oscilloscope waveform is as shown in the fi g-
ure below. (eye pattern)
A good eye pattern means that the diamond shape (
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
VOLT/DIV : 50 mV (10 : 1 probe in use)
TIME/DIV : 500 nS
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
Test Point:
– CD BOARD (Conductor Side) –
TP (RF OUT)
SECTION 6
ELECTRICAL ADJUSTMENTS
) in the
◊
RF level :
1.0 ± 0.2 Vp-p
60
41