Connectors
A node or network segment is connected to an 8-pin RJ-45 jack with securing collar. Due to
its flush fitting with an IE FC RJ-45 Plug 180 / IE FC RJ45 Plug 145 connector, the securing
collar ensures a robust connection suitable for industry that provides tensile and bending
strain relief for the inserted connector.
Note
The RJ-45 jacks of the SCALANCE X300EEC variants do not have a securing collar. The
tensile and bending relief are provided by the securing bracket using a cable binder, see also
section Signaling contact (Page 135).
4.3.1.2

1000Base-T

Transmission rate
The transmission rate of the electrical Ethernet ports is 10 Mbps, as Fast Ethernet ports 100
Mbps or as gigabit ports 1 Gbps.
Transmission mode
The transmission mode for 1000Base-T is specified in the IEEE 802.3ab standard.
Autonegotiation (automatic detection of the best transmission mode) is default.
The order in which they are selected is:
● 1000Base-T full duplex
● 1000Base-T half duplex
● 100Base-TX full duplex
● 100Base-TX half duplex
● 10Base-T full duplex
● 10Base-T half duplex
Two communication modes are possible:
● Half duplex
● Full duplex mode
SCALANCE X-300
Operating Instructions, 10/2010, A5E01113043-10
Two-way alternate transmission mode - it is only possible to either send or receive over
the interfaces at any one time.
Two-way simultaneous - both communication partners can send and receive at the same
time.