Honeywell VISTA-32FB Programming Manual page 3

Commercial fire and burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-32FB:
Table of Contents

Advertisement

Program feature or option
✱ 80 ZONE TYPE RESTORES
FOR TYPES 9, 10 & 14
1✱ 12 PROGRAM
NOTIFICATION SIGNAL
1✱ 13 SYSTEM SENSOR
REVERSING RELAY
1✱ 18 AFFECTS LOBBY
1✱ 19 ARMS LOBBY
1✱ 22thru 1✱ 25 CROSS-ZONING
PAIRS (1 – 4)
1✱ 28 RF TRANSMITTER LOW
BATTERY SOUND
1✱ 29 RF TRANSMITTER LOW
BATTERY REPORTING
1✱ 30 RF RECEIVER
SUPERVISION CHECK-IN
INTERVAL
1✱ 31 RF TRANSMITTER
CHECK-IN INTERVAL
1✱ 35 ACCESS CONTROL
DIALER ENABLES
1✱ 44 WIRELESS KEYPAD
TAMPER DETECTION
1✱ 45 EXIT DELAY SOUNDING
(PARTITION SPECIFIC)
1✱ 48 WIRELESS KEYPAD
ASSIGNMENT
1✱ 49 SUPPRESS TX
SUPERVISION SOUND
1✱ 53 DISABLE DOWNLOAD
CALLBACK
1✱ 57 5800 RF BUTTON
GLOBAL ARM
1✱ 58 5800 RF BUTTON FORCE
ARM
1✱ 60 ZONE 5 AUDIO ALARM
VERIFICATION
1✱ 72 EVENT LOG PRINTER
ONLINE
1✱ 73 PRINTER BAUD RATE
1✱ 76 CONTROL RELAY
(PART-SPECIFIC)
2✱ 07 AUTO-DISARM DELAY
(PART SPECIFIC)
2✱ 18 ENABLE GOTO FOR
THIS PARTITION (partition-
specific)
2✱ 21 SUPERVISION PULSES
FOR COMMUNICATIONS
DEVICE
2✱ 22 DISPLAY FIRE ALARMS
OF OTHER PARTITIONS
2✱ 23 DISPLAY BURG, PANIC
AND CO ALARMS FOR OTHER
PARTITIONS
Permitted in
Possible settings
UL864? Y/N
N
0 = disable
1 = enable
Y
0 = no
1 = yes
N
0=use neither Zone 1 or Zone 2 inputs
1=use Zone 1 input;
2=use Zone 2 input;
3=use Zone 1 and Zone 2 inputs.
N
0 = disable
1 = enable
N
0 = disable
1 = enable
N
Enter 001-032
Enter 000,000 to disable
N
0 = disarmed state only
1 = both armed and disarmed states
N
0 = disable
1 = enable
N
Enter 02–15 times 2 hours (4–30
hours)
Enter 00 to disable receiver
supervision
N
Enter 02–15 times 2 hours (4–30
hours)
Enter 00 to disable transmitter
supervision
N
0 = disable
1 = enable
N
0 = disable
1 = enable
N
0 = disable
1 = enable
N
0 = none
1-2 = partition number
N
0 = disable
1 = enable
N
0 = callback required
1 = no callback required
N
0 = disable
1 = enable
N
0 = disable
1 = enable
N
0 = disable
1 = enable
N
0 = disable
1 = enable
N
0 = 1200
1 = 300
N
01-96 = relay number
00 = relay not used.
N
00 = no delay.
01-14 times 4 minutes (04-56) delay.
15 = no auto disarming.
N
0 = disable
1 = enable
N
0 = disable
1 = enable
N
0 = disable
1 = enable
N
0 = disable
1 = enable
–3–
Settings permitted in UL 864
Must be set to "1" (enable) for zone
type 9.
Must be set to "1" (yes).
Not Used. Must be set to "0".
Must be set to "0" (disabled) for
partition 1.
Must be set to "0" (disabled) for
partition 1.
Must be set to "000,000" (disabled)
for fire zones.
Must be set to "1" (both armed and
disarmed states).
Must be set to "1" (enable).
Maximum is 02 (4 hours) for fire
installations.
Maximum is 02 (4 hours) for fire
installations.
Not used. Must be set to "0".
Not used. Must be set to "0".
Must be set to "0" (disable) for
partition 1.
Not used. Must be set to "0".
Must be set to "0" (disable).
Must be set to "0" (callback
required).
Must be set to "0" (disable).
Must be set to "0" (disable).
Must be set to "0" (disable).
Not used. Must be set to "0".
Not used.
Must be set to "00" (relay not used)
for partition 1.
Must be set to "15" (no auto
disarming) for partition 1.
Must be set to "0" (disable) for
partition 1.
Not used. Must be set to "00000"
(disable).
Must be set to "0" (disable) for
partition 1.
Must be set to "0" (disable) for
partition 1.