20.1" lcd monitor
Hide thumbs Also See for 200P7ES/00:
Table of Contents

Advertisement

200P7 LCD
24
Go to cover page
2. Access Factory Mode
- Turn off monitor.
-
[Push AUTO "
" & OK "
hold it ] + [Press power "
screen"] => then release all button
3. Click
(Write EDID) icon from the tool bar to write DDC data.
Step 6: Save DDC data
Sometimes, you may need to save DDC data as a text file for using
in other IC chip. To save DDC data, follow the steps below:
1. Click
(Save) icon (or click "file"-> "save as") from the tool bar
And give a file name as shown in Fig. 18.
The file type is EDID45 file (*.ddc) which can be open in WordPad.
By using WordPad, the texts of DDC data & table (128 bytes, hex
code) can be modified. If DDC TEXTS & HEX Table are completely
correct, it can be saved as .ddc flie to re-load it into DDC IC for DDC
Data application.
200P7 analog
200P7 analog
2.
Click
Save
.
Step 7: Exit DDC program
Pull down the File menu and select Exit as shown in Fig. 19.
Edid45.1
DDC Instructions
" buttons at the same time and
" button untill comes out "Windows
Fig. 25
Fig. 19
Step : 8 Modify serial number in OSD
-1. Unzip the serial number.zip to your computer, then open the folder
as shown in Fig.20.
-2. If use Win98 OS, you can execute SN.exe directly.
If use Win2000 or XP OS, first, you must execute install.bat, then
execute SN.exe
-3. Set I2C bus(press the left-top button of operating window) as shown
in Fig.21, then press " SET" button.
-4. Set Block2 as shown in Fig.22
-5. key in new serial number, then press " Write" button as shown in
Fig.22 , Click " WRITE" button.
-6. It will appear" Serial Number Write OK" , Click" Enter" to finish it.
Fig.18
Step9:
-1. Disconnect the monitor power cord and connect it again.
-2. Press the OK button to bring up the OSD main manu.
-3. Re-confirm the serial Number is updated as shown in Fig.23.