The MultiChecker V2 Series - more powerful
than ever!
Our highly acclaimed, compact A210 and A110 MultiChecker image processing units are now even more powerful! The V2
(Ver. 2) upgrade includes new functions for even greater convenience. To meet your diverse range of inspection
requirements, we have increased the number of checkers by a factor of three. In addition to making more inspection locations
possible, they now come equipped with a new mode that allows two-level branch inspection using one image checker, and an
extensive range of functions that allow use in a wide range of applications.
Three times the processing capacity
of their predecessors!
Designed to meet a diverse variety of
inspection needs!
You can now register
three times
more checkers per type!
GA210 MultiChecker: increased from 32 to
GA110 MultiChecker: increased from 16 to
Possible to choose from
three execution
modes to suit your
inspection requirements!
Automatic Switch Mode
Branch inspection without complicated
settings provides great convenience!
Example
It is possible to first make a direction judgment, and then perform a
separate inspection (character appearance or mark width measurement)
based on this direction.
Conventional method
GExecute all checkers and output results
GPerform direction judgment externally and compare results
Execution time: 65msec.
Automatic Switch Mode
GPerform direction judgment and execute the
required checker
Execution time:
35msec!
2
96
48
MICRO-IMAGECHECKER A210 and A110
Multichecker V2 (Photo shows A210)
Detect the direction
Execute block 1
judgment marker
(5 msec)
Normal direction
Reverse direction
Direction judgment
Execute Block 2
Execute Block 3
(30msec)
(30msec)
11/2004
New
New
User-Defined Mode
Multiple inspections of up to three blocks with no
switching time!
Example
When you wish to perform multiple continuous inspections because the
work will not fit in the field of view of a single image capture.
Conventional method
GHandled by type switching using an external device.
GType switching requires time and usage restrictions
apply.
User-Defined Mode
GInternally switches to the process block via an
external signal.
GExternal device is not used, so inspection time is
greatly reduced!
*Can be executed from the keypad as well.
Execute All Mode
Three times the number of checkers can now be registered per type, so you can
inspect many points at one time!
Example
Multiple simultaneous point inspection possible for applications
such as inspecting LED lighting.
Plenty of external outputs for judgment results (96 points for the
A210 and 48 points for the A110) allow simultaneous output of
judgment results for multiple inspection points.
Type switching not required!
Type 1
Type 2
First field of vision
Second field of vision
Third field of vision
(Block 1)
(Block 2)
(Block 3)
11/2004
Type 64
3