SERVICE TESTPROGRAM
VARIOUS TEST
Test planned for future software versions
- not implemented in all sets
END-USER DIAGNOSTICS
DISPLAY TEST
(CDR module)
To enter
END-USER DIAGNOSTICS
hold PLAY & REC LEVEL
buttons depressed while
plugging mainscord in.
On/Off switch in pos. ON
Insert CD-DA disc
before starting the test
Display shows for 3s each:
• Software version of
MOZART (flash ROM 7101)
• Software version of
basic engine processor
(flash EPROM 7017)
SDRAM TEST 7100
Display shows:
DTST1
CHECKSUM TEST 7101
Display shows:
DTST2
ERASE TEST 7101
Display shows:
DTST3
COMMUNICATION TEST
(UART-BUS)
Display shows:
DTST4
N
Y
TEST O.K.?
Flash Proms are set
to default settings.
CDR80x
Display shows:
Display shows:
FAILED
PASSED
Plug mains cord off
to exit
END-USER DIAGNOSTICS
CDR82x
5-6
SERVICE TESTPROGRAM
VARIOUS TESTS
QUARTZ TEST
N
REW 5 button
N
DISPLAY button
pressed?
pressed?
Y
Y
Tact frequency µ P
(divided 10MHz)
Display shows all
Display shows
segments and flags (dimmed)
10M
for checking open circuits.
see figure 1
1220±37Hz can be measur.
(pin 27 of µP).
on
1
All LEDs are switched on.
STOP button
N
STOP button
N
pressed?
pressed?
Y
Y
fig. 1
To enter Service
Testprogram hold
PLAY & CD3 buttons
depressed while
plugging mainscord in.
On/Off switch in pos. ON
Display shows
version number
of the µP - software.
S-CDR80-VXX
KEY TEST
FORMAT EEPROM
FFWD 6 button
N
CD TEXT button
pressed?
pressed?
Y
Y
1)
Display shows
Display shows
KEY --
NEW
Numbers acc. table 2
for 2s.
are indicated as long as a
EEPROM is cleared and
button is held depressed.
default values are stored.
If a button is pressed
on the Remote Control
KEY RC is shown
and the ; flag flashes.
This test should only be used to clear
the EEPROM in case of a µP-"hangup".
Attention: all data are set to default values,
BLACK BOX data are not cleared.
STOP button
N
pressed?
Y
1)
If the ON/OFF switch is in the position OFF , all other keys
are blocked and display will show 99 as long any key is
held depressed.
KEY
OPEN/CLOSE
(CDC)
CD CHANGE
AUX
CDR
DISPLAY
SHUFFLE

PROGRAM

CD TEXT
/EDIT
A-B EDIT
ERASE CD
FINALIZE CD
REC LEVEL
CD3
CD2
5-6
* To leave Service Testprogram plug mains cord off.
* In the main menu the sound settings (volume, ...),
trays and carousel work as in normal mode.
S
stands for Service mode
VXX
stands for Version number
of the software used in the
Front (Display) µP.
EEPROM TEST
N
N
PROGRAM button
pressed?
Y
Testpattern is written to
address 1
and
read back again
N
Test ok?
Y
Display shows
Display shows
ERR
PASS
STOP button
N
pressed?
Y
KEY CODES
KEY CODE
KEY
KEY CODE
0
CD1
14
1
COPY CD
15
2
COMPILE CD
16
3
RECORD
17
PLAY/PAUSE
18
4
5
5
20
NO
6
21
/CANCEL
6
7
22
YES
8
23
/ENTER
SPEED
9
24
(CDR820 only))
OPEN/CLOSE
10
25
(CDR)
11
ON/OFF
99
STOP
exit test
12
13
table 2
It`s Free
TEMPERATURE
(NTC) TEST
AUX button
N
pressed?
Y
Display shows
NTC XX
XX = value in °C
STOP button
N
pressed?
Y
CDR8xx servtest various, 07.09.01