Omega Engineering DP25-TH Quick Start

Thermistor indicator/controller

Advertisement

Quick Links

START HERE
Using This Quick Start Manual
Use this Quick Start Manual to set up your controller
and begin operation. Information is provided on how to:
¥
Connect ac power
¥
Connect sensor input
¥
Set basic options for operation
For complete information on all setup options, see the
OperatorÕs Manual.
Before You Begin
In addition to the controller and the related parts, you
will need the following items to set up your unit:
¥
ac power
¥
Sensor
¥
1
Ú
Ó flat blade screwdriver
8
PANEL THICKNESS
6,4 (.25) MAX
0,8 (.03) MIN
Mount the Meter
1,5
R(.06)
45,00 + 0,61/-0,00
1.
Cut a panel opening
4 PLCS
(1.772 + .024/Ð.000)
using the dimensions
shown to the right.
92,00 + 0,81/Ð0,00
(3.622 + .032/Ð.000)
2.
Position the unit in the
opening, making sure
NOTE: Dimensions in Millimeters (Inches)
the front bezel is flush with the panel.
Connect ac Power
Warning: Do not connect ac power to your meter
until you have completed all input and output
connections. Failure to do so may result in injury!
1.
Remove the panel at the back of the unit.
2.
Locate the TB1 connector.
3.
Insert the correct wire in each terminal as shown
in the following figure and tighten the lockdown
screws. Tug gently on the wires to verify
connections.
VERSION #1
VERSION #2
TB1
TB1
1
2
3
4
5
6
1
2
3
4
5
6
TB3
TB2
1
2
3
7
8
9
10 11 12
1
2
7
8
9
10 11 12
EARTH
GROUND
NEUTRAL
LINE
AC POWER
FUSE
Main ac Power Connections
2
Connecting the Sensor Input
1.
Locate the TB2 (TB3 on Version #1) connector on
the rear of the unit.
2.
Connect sensors, referring to the appropriate
diagram below and tighten down lockdown
screws.
3.
Tug gently on the wires to verify the connections.
4.
Replace the panel at the back of the unit.
2
1
+S
-S
2-Wire Input (400 Series)
1
2
+S
-S
3-Wire Input (700 Series)
Hook up Alarm 1 (Setpoint) (refer to TB1 Main
ac Power Connection Drawing)
1.
Connect a jumper from ac Line (Terminal 7) to
Relay 1 Common (Terminal 3).
2.
Connect Relay 1 Normally Open (Terminal 1) to
External Alarm ac Line.
3.
Connect External Alarm to ac Neutral (Terminal 8).
Hook up Alarm 2 (Setpoint) (refer to TB1 Main
ac Power Connection Drawing)
3
1.
Connect a jumper from ac Line (Terminal 7) to
Relay 2 Common (Terminal 6).
2.
Connect Relay 2 Normally Open (Terminal 4) to
External Alarm ac Line.
3.
Connect External Alarm to ac Neutral (Terminal 8).
Turn on the Unit
1.
Apply power to the unit. The unit initializes,
flashing ÒTHERMISTORÓ. Then the temperature
should appear.
2.
Verify that a temperature is displayed. If not:
¥
Remove ac power
¥
Verify the TB1 power connections
¥
Check your power source
¥
Apply power again
3
-R
Configure the Unit
To configure the unit, use the buttons on the controllerÕs
front panel.
To:
Display the
Configuration
Menu.
3
Select the
-R
submenu
function.
Select a value
for that submenu
function.
Go back to the
previous menu
function.
Exit the
Configuration
Menu.
3
To Change the Input Type:
1.
2.
3.
4.
Take This Action
5.
Press the MENU button.
The first function on the
menu, ÒINPTÓ, displays.
1. Press MENU until the
function you want is shown.
2. Press
/MIN.
To Change the Decimal Point:
1. Press
/MAX. to display
the option you want.
1.
2. Press MENU to select it.
ÒSTRDÓ quickly flashes,
indicating that the selection
has been stored in memory.
Then the next menu function
displays.
2.
Press RESET once.
¥ Press RESET twice. The
unit reinitializes (displays
3.
ÒRSTÓ, then ÒTHERMISTORÓ).
When the temperature
displays, the meter is back in
4.
Run Mode.
5.
¥ Optionally, you can press
MENU to move through all
the menu functions until the
meter reinitializes.
4
Press MENU until the display
shows ÒINPTÓ:
SETPTS
/MAX
/MIN
MENU
Press
/MIN to show current input
type:
SETPTS
/MAX
/MIN
MENU
Press
/MAX to select the setting.
Choices are: 4004, 4005, 4006,
4007, 4008, 4017, 4018 and 700.
SETPTS
/MAX
/MIN
MENU
Press MENU to store the value.
Press RESET twice to display the current
temperature.
SETPTS
/MAX
/MIN
MENU
RESET
SETPTS
/MAX
/MIN
MENU
Press MENU until the display
shows ÒDEC.PÓ:
SETPTS
/MAX
/MIN
MENU
Press
/MIN to show the current
decimal point location:
SETPTS
/MAX
/MIN
MENU
Press
/MAX to select the setting.
Choices are: ÒFFF.FÓ, ÒFFFF.Ó or
ÒFF.FFÓ.
/MAX
SETPTS
/MIN
MENU
Press MENU to store the value.
Press RESET twice to display the current
temperature.
SETPTS
/MAX
/MIN
MENU
RESET
SETPTS
/MAX
/MIN
MENU
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET

Advertisement

loading

Summary of Contents for Omega Engineering DP25-TH

  • Page 1 START HERE Using This Quick Start Manual Connecting the Sensor Input Use this Quick Start Manual to set up your controller and begin operation. Information is provided on how to: ¥ Connect ac power ¥ Connect sensor input ¥ Set basic options for operation For complete information on all setup options, see the OperatorÕs Manual.