SPECIFICATIONS

TYPE
INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY
HEATING CAPACITY

ELECTRICAL DATA

POWER SOURCE
FREQUENCY
RUNNING CURRENT
INPUT WATTS
E.E.R.
COP
MOISTURE REMOVAL
AIR CIRCULATION-High
(m /hr)
3
COMPRESSOR
TYPE
DISCRIMINATION
REFRIGERANT
FAN MOTOR
POWER SOURCE
INDOOR UNIT
OUTDOOR UNIT
2006.01.10
COOL & HEAT INVERTER
ASYA12LCC
AOYR12LCC
3.50 kW
4.80 kW
COOLING
HEATING
COOLING
0.92 kW
HEATING
1.24 kW
COOLING
3.80 kW/kW
HEATING
3.87 kW/kW
( /hr)
1.8 L/hr
COOLING
635 m3/hr
HEATING
670 m3/hr
Hermetic type, 4 pole, 3 phase,
DC inverter motor, Rotary
DA89X1C - 20FZ
R410A
1,050 g
Cool 1,370 / Heat 1,440 r.p.m.
HIGH-SPEED
Cool 1,150 / Heat 1,200 r.p.m.
MED-SPEED
LOW-SPEED
Cool 950 / Heat 1,000 r.p.m.
QUIET
Cool 700 / Heat 760 r.p.m.
830 r.p.m.
DIMENSIONS
INDOOR UNIT
OUTDOOR UNIT
WEIGHT
INDOOR UNIT
OUTDOOR UNIT

NOISE LEVEL

230 V
50 Hz
4.3 A
INDOOR UNIT
5.6 A
OUTDOOR UNIT
REFRIGERANT (R410A)
FULL CHARGE AMOUNT
ADDITIONAL REFRIGERANT
MAXIMUM PIPING HEIGHT
230 V
1
275 x 790 x 215 mm
H x W x D
540 x 790 x 290 mm
H x W x D
GROSS / NET
GROSS / NET
High
Cool 42 dB / Heat 42 dB
Med
Cool 36 dB / Heat 35 dB
Low
Cool 30 dB / Heat 29 dB
Quiet
Cool 21 dB / Heat 21 dB
Cool 47 dB / Heat 49 dB
Pipe Length
15 m
20 m
12 / 9 kg
41 / 37 kg
1,050 g
1,150 g
20 g / m
15m