Selection Data; Specifications - Mitsubishi SRK09CH Technical Manual & Parts List

Table of Contents

Advertisement

1.2 SELECTION DATA

1.2.1 Specifications

Model
SRK09CH (Indoor unit)
SRC09CH (Outdoor unit)
Item
(1)
Cooling capacity
Power source
Cooling input
Running current (Cooling)
Inrush current
COP (In cooling)
(4)
Noise level
Exterior dimensions
Height × Width × Depth
Color
Net weight
Refrigerant equipment
Compressor types & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
(3)
Refrigerant oil
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Recommended breaker size
Size × Core number
Connection
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
(2) The operation data are applied to the 220 V or 230 V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 7.5 to 15 m, add 10 g refrigerant per meter.
(4) Expressed in sound pressure level.
Model
kW
BTU/h
kW
A
A
dB
mm
kg
kW
kg
R
W
CMM
HI POWER (Green), ECONO (Orange)
mm (in)
A
Item
Indoor air temperature
DB
27°C
SRK09CH
1 Phase, 220/230V, 50Hz
41
268 × 790 × 224
Fine snow
8.0
Louver fins & inner grooved tubing
R22 0.43 (Pre-Charged up to the piping length of 7.5m)
0.28 (SUNISO 4GSI or ATMOS NM56)
Tangential fan × 1
14
9.0
Polypropylene net (washable) × 2
Wireless-Remote control
Microcomputer thermostat
RUN (Green), TIMER (Yellow),
Frost protection,
Fan motor error protection
Liquid line: ø6.35 (1/4") Gas line: ø9.52 (3/8")
Flare connecting
Liquid line: 0.4 m
Gas line : 0.33 m
Necessary (Both sides)
2.5 m (3 cores with Earth)
× 3 cores (Including earth cable)
1.5 mm
2
Terminal block (Screw fixing type)
Outdoor air temperature
WB
DB
19°C
35°C
4
-
-
SRC09CH
2.64
9000
0.90
4.2
18
2.93
49
540 × 645 × 245
Polar white
27
RSA201A034
0.68
Line starting
Louver fins & grooved tubing
Capillary tubes
Propeller fan × 1
22
24
Cushion rubber (for compressor)
Thermostat (for compressor)
Connectable
20
Mounting kit
WB
24°C
(220/230V)
Standards
ISO-T1, JIS C9612