9.3.
P.C.B. (Printed Circuit Board) exchange
9.3.1.
Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
9.3.2.
Quick adjustment after P.C.B. exchange
P.C.B.
P Board
Vsus
Vda
PFC
Vlow
Csus
SC Board
Vad
SS Board
Ve
D, DG Board
White blance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
9.4.

Adjustment Volume Location

9.5.

Test Point Location

Name
Test Point
TPVSUS (SS)
TPVDA (SS)
C446 (+) (-) (P)
C557 (+) (-) (P)
TPVSUS (SS)
TPVAD (SC)
TPVE (SS)
Voltage
Volume
Vsus ± 2V
R628 (P)
67V ± 1V
R665 (P)
395V ± 0.5V
R443 (P)
73V ± 0.1V
R661 (P)
178V ± 0.5V
R671 (P)
-90V ± 1V
VR6477 (SC)
Ve ± 2V
VR6074 (SS)