On-Screen Messages - Yamaha RIVAGE PM10 Owner's Manual

Signal processor dsp-r10
Hide thumbs Also See for RIVAGE PM10:
Table of Contents

Advertisement

On-screen Messages

An error message for caution or attention will be displayed on the front panel LCD, and will be indicated via the color
indicator.
Error messages indicating caution
Repair might be required. Contact your Yamaha dealer.
Color
LCD
Indicator
Message
Status
1 [ERR M0*]
Red
H/W ERROR
(flashing)
MY SLOT*
1 [ERR H0*]
Red
H/W ERROR
(flashing)
HY SLOT*
1 [ERR T11]
Red
TWINLANe
(flashing)
T V B OP IP
1 [ERR X0*]
Red
H/W ERROR
(flashing)
1 [ERR F01]
Red
COOLING FAN
(flashing)
ERROR
Error messages indicating a need for attention
Color
LCD
Indicator
Message
Status
1 [ERR T0*]
TWINLANe
WRONG LOOP
Red
(flashing)
1 [ERR T12]
TWINLANe
T V B OP IP
Yellow
(lit steadily)
1 [ERR P01]
Yellow
POWER A OFF
(lit steadily)
1 [ERR P02]
Yellow
POWER B OFF
(lit steadily)
1 [ERR C11]
Yellow
LOW BATT
(lit steadily)
1 [ERR C12]
Yellow
NO BATT
(lit steadily)
NOTE
If multiple issues occur at the same time, press the [U] or [D] key to view the corresponding error messages.
A card inserted in the MY card slot is not accessible.
An asterisk mark (*) indicates the slot number in relation with the corresponding error.
A card inserted in the HY card slot is not accessible.
An asterisk mark (*) indicates the slot number in relation with the corresponding error.
The optical transceiver module on the HY256-TL is faulty.
T: Temperature, V: Voltage, B: Bias current, OP: Output Power, IP: Input Power
This error may be resolved by the possible solution described below for M1[ERR T12].
One of the internal parts is faulty.
An asterisk mark (*) indicates the internal part that has caused the corresponding error.
The cooling fans are faulty.
Description
Fiber optic cable is not connected properly.
An asterisk mark (*) indicates the error
description.
T01: Signal is looped back to the unit itself
(IN-OUT).
T02: Input connectors are connected to
each other (IN-IN).
T03: Output connectors are connected to
each other (OUT-OUT).
An error has occurred with the optical
transceiver module on the HY256-TL.
T: Temperature, V: Voltage, B: Bias current,
OP: Output Power, IP: Input Power
Power is not supplied from power supply
unit A.
Power is not supplied from power supply
unit B.
The backup battery voltage is down to 2.8V
or lower.
The backup battery voltage is down to
2.45V or lower.
Description
Possible solution
Check the cable connection.
• Make sure that the cable is securely inserted.
• Use a commercially-available cleaning tool for fiber
optics to clean both ends of the cable and the
connectors on the card.
• Change to a different cable.
If the solutions above do not resolve the issue, have
the unit checked by an authorized technician,
although the problem will not affect operation of the
unit. Please contact your Yamaha dealer.
Make sure that the power switch on power supply unit
A is turned on, and that the power cord is connected
to the unit and power supply unit A.
Make sure that the power switch on power supply unit
B is turned on, and that the power cord is connected
to the unit and power supply unit B.
Please contact your Yamaha dealer immediately and
have qualified Yamaha service personnel replace the
backup battery.
Please contact your Yamaha dealer immediately and
have qualified Yamaha service personnel replace the
backup battery.
DSP-R10 Owner's Manual
17

Advertisement

Table of Contents
loading

Table of Contents