Technical information

Hob dimensions
Width
Depth
Other technical data
TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
Bypass diameters
BURNER
Triple Crown
Semi-rapid
Auxiliary
Gas burners for NATURAL GAS G20/G25 20/25 mbar (BE) - G20 20 mbar (LU)
BURNER
Triple Crown
Semi-rapid
Auxiliary
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
Triple Crown
3,8
28
Gas original:
Gas replacement:
230 V ~ 50 Hz
II2E+3+ (BE)
I2E (LU)
R 1/2"
3
56
32
28
NORMAL POWER kW
3,8
1,9
1,0
MINIMUM
POWER
kW
kW
1,4
740 mm
510 mm
G20/G25 (2E+) 20/25 mbar (BE) = 10,5 kW
G20 (2E) 20 mbar (LU) = 10,5 kW
G30 (3+) 28-30 mbar = 763 g/h
G31 (3+) 37 mbar = 750 g/h
Ø BYPASS 1/100 mm
MINIMUM POWER kW
1,4
0,45
0,33
INJECTOR
MARK 1/100
mm
G30 28-30
98
276
INJECTOR MARK
1/100 mm
146
96
70
NOMINAL GAS FLOW g/h
G31 37 mbar
mbar
271