Advertisement

Honda Motor Europe Ltd.
EM2300
OWNER'S MANUAL
Original Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Honda EM2300

  • Page 1 Honda Motor Europe Ltd. EM2300 OWNER’S MANUAL Original Instructions...
  • Page 2 All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Europe, Ltd. reserves the right to make changes at any time without notice and without incurring any obligation.
  • Page 3: Table Of Contents

    CONTENTS 1. SAFETY INSTRUCTIONS 2. SAFETY LABEL LOCATIONS 3. COMPONENT IDENTIFICATION 4. PRE-OPERATION CHECK 5. STARTING THE ENGINE 6. GENERATOR USE 7. STOPPING THE ENGINE 8. MAINTENANCE 9. TRANSPORTING/STORAGE 10. TROUBLESHOOTING 11. SPECIFICATIONS 12. WIRING DIAGRAM EC Declaration Of Conformity...
  • Page 4: Safety Instructions

    Do not operate the generator with any cover removed. You may get your hand or foot caught in the generator and it may cause accident. Consult your authorized Honda dealer for disassembly and service of the generator that are not covered in this manual.
  • Page 5 Carbon Monoxide Hazards Exhaust contains poisonous carbon monoxide, a colorless, odorless gas. Breathing exhaust can cause loss of consciousness and may lead to death. If you run the generator in an area that is confined, or even partially enclosed area, the air you breathe could contain a dangerous amount of exhaust gas. Never run your generator inside a garage, house, or near open windows or doors.
  • Page 6 To protect the environment, do not dispose of the used generator, battery, engine oil, etc. carelessly by leaving them in the waste. Observe the local laws or regulations or consult your authorized Honda generator dealer to dispose of these parts.
  • Page 7: Safety Label Locations

    These labels warn you of potential hazards that can cause serious injury. Read the labels and safety notes and precautions described in this manual carefully. If a label comes off or becomes hard to read, contact your Honda dealer for a replacement. Connect Caution Read Owner’s Manual...
  • Page 8 • Honda generators are designed to give safe and dependable service if operated according to instructions. Read and understand the Owner’s Manual before operating the generator. Failure to do so could result in personal injury or equipment damage. • Exhaust contains poisonous carbon monoxide, a colorless, odorless gas.
  • Page 9 CE Mark and Noise Label Locations Performance Class Noise Label Quality Class IP Code Dry Mass Manufacturer Year of Name and address of authorized and address manufacture representative Name and address of manufacturer and authorized representative are written in the “EC Declaration of Conformity” CONTENT OUTLINE in this Owner’s Manual.
  • Page 10: Component Identification

    3. COMPONENT IDENTIFICATION Control Function - Illustration 1. Fuel tank cap 2. Oil level indicator 3. Fuel tank 4. Ground Terminal 5. Dipstick 6. Oil drain plug 7. Muffler 8. Spark plug 9. Choke adjustment lever 10. Recoil starter 11. Fuel valve lever 12.
  • Page 11 “ON” 2. O “OFF” CAUTION: Control the load within the generator rated output when the AC circuit breaker shuts off. If the AC circuit breaker shuts off again, ask your authorized Honda dealer for help.
  • Page 12: Pre-Operation Check

    4. PRE-OPERATION CHECK CAUTION: Be sure to check the generator on a level surface with the engine stopped. 1.Check the engine oil level before each use. CAUTION: Using non detergent oil or 2-stroke engine oil could shorten the engine’s service life. Use 4-stroke motor oil that meets or exceeds the requirements for API service category SE or later (or equivalent).
  • Page 13 2.Check the fuel level. Check the fuel gauge. If the fuel level is low, refuel the fuel tank until the level as specified. After refueling, tighten the fuel tank cap securely. Use automotive unleaded gasoline with a Research Octane Number of 93 or higher.
  • Page 14 Gasolines Containing Alcohol If you decide to use a gasoline containing alcohol (gasohol), be sure its octane rating is at least as high as that recommended by Honda. There are two types of ‘‘gasohol’’: one containing ethanol, and the other containing methanol.
  • Page 15 3.Check the air filter. Check the air filter element to be sure it is clean and in good condition. Unsnap the two air cleaner cover clips, remove the air cleaner cover, and remove the air cleaner element. Clean or replace the element if necessary (see page 23). CAUTION: Never run the engine without the air filter element.
  • Page 16: Starting The Engine

    5. STARTING THE ENGINE CAUTION: When starting the generator after adding fuel for the first time, after long-term storage, or after running out of fuel, turn the fuel valve lever to the ON position, then wait for 10 to 20 seconds before starting the engine.
  • Page 17 High altitude performance can be improved by specific modifications to the carburetor. If you always operate the generator at altitudes higher than 1,500 meters (5,000 feet) above sea level, have your authorized Honda dealer perform these carburetor modifications. Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each 300 meter (1,000 foot) increase in altitude.
  • Page 18: Generator Use

    6. GENERATOR USE The generator produces enough electric power to cause a serious shock or electrocution if misused. Be sure to ground the generator when the connected appliance is grounded. To ground the terminal of the generator, use a copper wire with same or larger diameter than the cord of the connected appliance.
  • Page 19 Most appliance motors require more than their rated wattage for startup. Make sure the electrical rating of the tool or appliance does not exceed the maximum power rating of the generator. Maximum power is: EM2300: 2.3kVA • For continuous operation, do not exceed the rated power.
  • Page 20 AC Appliances Plug in AC appliances using below sequence: 1. Start the engine (see page 15) 2. Confirm the appliance to be used is switched off 3. Plug in the appliance and switch the AC circuit breaker “ON” (1) 4. Turn on the appliance CAUTION: •...
  • Page 21: Stopping The Engine

    7. STOPPING THE ENGINE CAUTION: Before stopping the engine, make sure all electric devices plugged into the generator are turned OFF. Stop the engine using below sequence: 1. Turn the circuit breaker to “OFF“ 2. Turn the engine switch to “STOP“ 3.
  • Page 22: Maintenance

    (1) For commercial use, log hours of operation to determine proper maintenance intervals. (2) Service more frequently when used in dusty areas. (3) These items should be serviced by your servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to Honda shop manual for service procedures.
  • Page 23 1. CHANGING OIL 1. Place the machine on a flat surface and run the engine several minutes to heat up the oil. This will assure rapid and complete draining of the oil. Then stop the engine. 2. Clean the peripheral region of oil filler plug and dipstick. Then disassemble the oil filler plug, dipstick and drain plug.
  • Page 24 2. AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. Do not use gasoline or low flash point solvents for cleaning. They are flammable and explosive under certain conditions.
  • Page 25 3. FUEL SEDIMENT CUP SERVICE Gasoline is extremely flammable and is explosive under certain conditions. Do not smoke or allow flames or sparks in the area. The sediment cup prevents dirt or water that may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned.
  • Page 26 4. SPARK PLUG SERVICE Recommended spark plugs: BPR6ES (NGK) W20EPR-U (DENSO) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. CAUTION: If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler.
  • Page 27: Transporting/Storage

    9. TRANSPORTING/STORAGE 1. TRANSPORTING To prevent fuel spillage when transporting or during temporary storage, the generator should be secured upright in its normal operating position, with the engine switch to STOP. The fuel valve lever should be turned OFF. When transporting the generator: •...
  • Page 28 2. STORAGE 1. Turn the fuel valve lever to the OFF position. 2. Place a suitable gasoline container below the carburetor, and use a funnel to avoid spilling fuel. 3. Loosen the carburetor drain screw and drain the gasoline from the carburetor.
  • Page 29: Troubleshooting

    10. TROUBLESHOOTING When the engine will not start : Refill the fuel tank Is there fuel in (see page 12) the tank? Turn the fuel valve Is the fuel valve lever to ON lever ON? (see page 15) Turn the panel Is the engine panel switch ON switch ON?
  • Page 30 When there is no electricity at the AC receptacles : Turn the AC circuit Is the AC circuit breaker ON breaker ON? (see page 19) NO DEFECTS Check the electrical Take the generator appliance or to your servicing equipment for any dealer.
  • Page 31: Specifications

    11. SPECIFICATIONS Specifications Model - Type EM2300 B Rated Frequency (Hz) Rated Power (kVA) Rated Voltage (V) 115/230 Phase Single Power Factor (cosφ) Insulation Level DC Output Engine Model Honda GX160H Engine Type Forced air-cooled, 4-stroke, OHV, Transistor Displacement (cc) Cylinder diam.
  • Page 32 Noise Model EM2300 Type Sound pressure level at the 79 dB (A) workstation (2006/42/EC) Uncertainty 1 dB (A) Measured sound power level 93 dB (A) (2000/14/EC, 2005/88/EC) Uncertainty 1 dB (A) Guaranteed sound power level 94 dB (A) (2000/14/EC, 2005/88/EC) The figures quoted are emission levels and are not necessarily safe working levels.
  • Page 33: Wiring Diagram

    12. WIRING DIAGRAM...
  • Page 34: Ec Declaration Of Conformity

    EM2300 JSLE 1000001-9999999 Manufacturer Authorized representative and able to compile the technical documentation Honda Mindong Generator Co Ltd. No 7, Houyou Road Honda Motor Europe Ltd. Fuxing Economic Development Zone, Cain Road, Bracknell, RG12 1HL Fuzhou City, Fujian Province United Kingdom P.R.

Table of Contents