Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
BROIL ELEMENT
Outer
Element
Element
Refer to page 4-10 for the procedure for ac-
cessing the broil element.
1.
Unplug oven or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads across the
wire connector terminals. The meter should
indicate as shown below:
Inner Element: The meter should indicate
between 31 and 36 Ω.
Outer Element: The meter should indicate
between 53 and 59 Ω.
Inner
Outer
Element
WARNING
Electrical Shock Hazard
HIDDEN BAKE ELEMENT
Refer to page 4-18 for the procedure for ac-
cessing the hidden bake element.
1.
Unplug oven or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads across wire
connector terminals. The meter should
indicate between 26 and 30 Ω.
5-3