6. ELECTRIC SIGNAL CONNECTION

6.1 Wiring precautions

(1)If noise enters the IJ printer from the outside, there is the danger of erroneous operation or trouble.
To improve noise resistance, perform wiring work as follows:
1
Separate the power cable to the IJ printer from other power lines for powering use (especially, power
line for a speed control inverter, etc.).
Wiring the power cable through a separate duct is even better.
2
Do not bundle input/output (I/O) signal wiring together with other power lines. Wire them
independently instead.
3
Electrically isolate the print target detector, print head, stand, and IJ printer body from other
machinery and equipment (conveyor, etc.).
4
Separate the print target detector wiring from other power lines.
Perform that all electrical wiring, connections and grounding comply with applicable cords.
5
(When erroneous operation was caused by noise, etc., use a dedicated ground.)
Print stop
Ready
(2) Connection to power supply
Use a suitable plug and always connect the power source to a protective ground. In addition, arrange the
receptacles near the IJ printer so that removal is easy.
IJ printer body
5 Ground
1 Primary power source
Print target
Stand
Print head
3
4
Print target detector
Conveyor
M
Motor power line
●Wiring precautions 6-1