Using The Metal Finder Function; Using The Wire Detector Function; Battery; Technical Data - Black & Decker LZR210 Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
ENGLISH
When the red LED indicator (4) lights up, slow down and
x
slide the tool further until the buzzer sounds and the top
green LED indicator is on.
This position indicates the other edge of the stud.
Mark this position through the hole in the marking insert (7).
x
The centre of the stud is between the two marks.
Using the metal finder function (fig. E)
You can use this function to find metal pipes through drywall
boards up to 18 mm thick.
Fit the marking insert (7).
x
Set the mode selector switch (3) to the 'METAL' position.
x
Place the tool flat against the wall as shown.
x
Keep the on/off switch (2) depressed.
x
The red LED indicator (4) will light up and the buzzer will sound
once while the tool is calibrating. After calibration is completed:
While holding the unit with one hand place your other
x
hand on the surface close to the area being scanned.
Move the tool slowly and smoothly across the surface,
x
approaching from different directions.
When the red LED indicator (4) lights up, slow down and
x
slide the tool further until the buzzer sounds and the top
green LED indicator is on.
This position indicates the location of a metal object.
After detecting the work area repeat the testing
x
procedure to confirm the operation of the unit.
Using the wire detector function (fig. F)
You can use this function to find live wires through drywall
boards up to 38 mm thick. The function works continuously in
all modes.
Warning! Test the unit on a known AC current before use.
Make sure the unit is away from the area being scanned
x
and any other AC current source. Static charge may
interfere detection on both sides of the wire, resulting in
limited accuracy.
Keep the on/off switch (2) depressed.
x
The red LED indicator (4) will light up and the buzzer will sound
once while the tool is calibrating. After calibration is completed:
While holding the unit with one hand place your other
x
hand on the surface close to the area being scanned.
Move the tool slowly and smoothly across the surface,
x
approaching from different directions.
When an AC source is located, the red LED indicator (5) will blink.
After detecting the work area repeat the testing
x
procedure to confirm the operation of the unit.

Protecting the environment

Separate collection. This product must not be
disposed of with normal household waste.
6
Should you find one day that your Black & Decker product
needs replacement, or if it is of no further use to you, do not
dispose of it with household waste. Make this product
available for separate collection.
Separate collection of used products and packaging
allows materials to be recycled and used again.
Re-use of recycled materials helps prevent
environmental pollution and reduces the demand for
raw materials.
Local regulations may provide for separate collection of
electrical products from the household, at municipal waste
sites or by the retailer when you purchase a new product.
Black & Decker provides a facility for the collection and
recycling of Black & Decker products once they have reached
the end of their working life. To take advantage of this service
please return your product to any authorised repair agent who
will collect them on our behalf.
You can check the location of your nearest authorised repair
agent by contacting your local Black & Decker office at the
address indicated in this manual. Alternatively, a list of
authorised Black & Decker repair agents and full details of our
after-sales service and contacts are available on the Internet
at: www.2helpU.com

Battery

At the end of their useful life, discard batteries with
due care for our environment.
Remove the battery as described above.
x
Place the battery in a suitable packaging to ensure that
x
the terminals cannot be short-circuited.
Take the battery to a local recycling station.
x

Technical data

Voltage
Battery size
Operating temperature
Wave length
Laser class
Laser power
Weight
LZR210
V
9
6LR61
°C
0 - 40
nm
630-675
2
mW
< 2.2
kg
0.45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents