Triac Replacement

Motor Capacitor
Black Box
Fuse Holder
Control PCB
Transformer
ZV750
1. Access triac (refer to Component Access/
Duct Cover Removal).
Note: The triac is located on the right side of
Model ZV750 and on the front of Model ZV850.
See Electronic Hood Control Description for
ZV850 diagram.
2. Remove 2 screws and the triac cover from
the hood.
3. Unplug 3 connectors from the triac.
4. Remove 2 screws and the triac from the hood.
5. Replace the triac with a new triac.
Note: When reinstalling, ensure that all electrical
connections are securely fastened and in the
correct location (ref. – mini manual).
3/16"
Terminal
1/4"
Black
Terminals
Orange
3/16"
Brown
Terminal
Triac
– 16 –
Brown
1/4"
Terminals
Black
Orange
Triac
Motor
Capacitor
Control PCB
Black Box
Fuse Holder
ZV850
GEA00016