Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Natural Draft Electronic Model Type 2: Natural Draft Ignition approved for the Electronic Ignition Gas Fireplace following models DATA PLATE: Refer to data plate for information in SUITABLE GAS BURNER OPTION respect to gas pressure, consumption and gas type, Natural or LPG.
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Before Installation Installation The Natural Draft Electronic Ignition (N.D.E.I.) flue N.D.E.I. system supplied with system shall be installed by authorized personnel in required electrical fittings. Work needs to be accordance with the manufacturer’s installation...
Page 4
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Measurement and Specifications of N.D.E.I LIP FRAME DETAIL 3 PIN PLUG TYP. 240 VOLT ON/OFF SWITCH 10MM ON/OFF SWITCH 10 AMP TO BURNER FRONT OF SHEETING TO BURNER ISOLATING FIREPLACE SWITCH...
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces FRAMING DIMENSIONS DOUBLE SIDED DOUBLE SIDED 700 LOW LINE 1056 1050 850 LOW LINE 1145 1145 1100 LOW LINE 1408 1145 1500 LOW LINE 1796 1280 2000 LOW LINE 2293 1280 B* INCLUDING 10mm PLASTERBOARD C* - INTERNAL FRAME HEIGHT WHEN USING HEAT ZONE KIT.
Page 6
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces HEAT ZONE CONVERSION CASING ACTIVE FLUE STANDARD VENT FULL WELD HOLES HEATZONE SECTION A-A FAN ( 300MM x 105MM ) OPTIONAL SECOND 300 MIN. TO VERTICAL SURFACE (CEILING) 137 MM. SPIRAL DUCT 150MM MAX.
Page 8
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces SECTIONS AGA APPROVED GAS COWL AGA APPROVED GAS COWL APPROVED FLASHING APPROVED FLASHING 25MM MIN. FLUE CLEARANCE TO TIMBER 25MM MIN. FLUE CLEARANCE TO TIMBER FRAMEWORK AND 10MM WALL FRAMEWORK LINING BY...
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire – Gas Installation Check unit is suitable for intended gas supply. Coal & Pebble Note position on gas appliance on drawing • Evenly spread a bag of Vermiculite into the burner specification on right hand side of appliance.
Page 10
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire – Coal & Pebble MARK 2 COALS 700/800 – 600 X 155 MARK 2 PEBBLES 700/800 – 600 X 155 MARK 2 COALS 1000 – 992 X 135 MARK 2 PEBBLES 1000 –...
Page 11
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 850 Ceramic Log P O S I T I O N I N G O F A L L L O G S • It is important to follow the log recommended 2 .
Page 12
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 850 Ceramic Log 4 . LOCATE LOG NO. 4. Place it on the left 6. LOCATEL O G N O. 9 . This log is placed on the log in the centre of the burner.
Page 13
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire – 700 Ceramic Log P O S I T I O N I N G OF A L L L O G S • It is important to follow the recommended positioning.
Page 14
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 700 Ceramic Log 4 . LOC ATE LOG NO. 4. This log is placed 6 . L O C AT E L O G N O. 7 : The charred with the thinner edge on the smaller coal.
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Commissioning Procedure Installed correctly the burner should not emit any 2 Initially the Kemlan coal fire may burn with a fumes into the room. The following procedure should be slightly blue flame. After approximately 20 minutes undertaken to test that the unit is operating correctly.
Wiring Diagram Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces For further service information contact Kemlan Australia Head Office –13 French Avenue, Brendale, Queensland 4500 Telephone –PH: (07) 3490 5500...
Page 17
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Service Instructions for Direct Ignition and Power Flue Horizon fireplaces. POWER FLUE SERVICE INSTRUCTIONS PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION PILOT WILL NOT LIGHT WITH FAN -CHECK FOR GAS SUPPLY AND TURN ON...
Page 18
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces DIRECT IGNITION PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION -CHECK FOR GAS SUPPLY AND TURN ON ALL CONNECTIONS PILOT WILL NOT LIGHT 1)NO GAS -CHECK GAS PRESSURE -CHECK PILOT AND CLEAN INJECTOR -CHECK ELECTRIC SUPPLY AND...
Page 19
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Trouble shooting guide for Techrite ignition pack Warning: This is a 240VAC module. All connections to the module are 240V (except ignition cable and flame sense). Ensure power is switched off before checking any connection or replacing any components.
Page 20
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Flash Code Meaning Possible Cause (Red LED) Pressure switch fail Check combustion fan. Check unit has started and pressure switch and connections. during heat cycle the Check flue for obstructions pressure switch has...
Page 21
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces TAIS Flash Codes LED Flash Code Descriptions Flash Code (Long flashes– Description short flashes) Normal Start Up Operation Normal Running State Flame failure Waiting for pressure switch ON Waiting for pressure switch to go OFF...