3 7 63 1515 0

ERROR MESSAGE

When stopped by any cause, press "STOP" of the remote control while pressing and holding the "STOP" on the
panel key. The operation mode turns to the mode allowing the display of messages.
The unit hold the latest error message in EEPROM. So even if stopped with no error, the unit can display the
latest error massage with same operation. (Except for CDC-585/CDC-506, which have no EEPROM. )
Error Messages List
ERROR
MESSAGE
E — X 0
Data cannot be read after finishing search.
E — X 1
Data cannot be read during PLAY (x = 0), PAUSE (x = 3) or SCAN (x = 2).
E — 7 1
At the start, tracking servo is not effective.
E — 7 2
At the start, spindle servo PLL is not effective.
E — 7 3
At the start, data can not read.
E — X 4
Close switch does not work with tray closed.
E — X 5
Open switch does not work with tray opened.
E — X 6
Table does not turn.
E — X 7
Traverse (Feed) inner circumference switch does not work.
E — X 8
Recovery action fails after focus drop.
E — X 9
Clamp down switch does not work.
E — X A
Clamp up switch does not work.
E r r
MN35511 does not give response of SENSE, with resetting by the unit's
microcomputer.
TE
L 13942296513
1) Error Code Troubleshooting
X0 , X1 , 73 .....
Error codes
Is disc dirty or
scratched?
Pick-up position
Pick-up defective, Spindle system
defective. (Motor fails to run, etc.)
X4 , X5
Error codes
Does tray
operate when
OPEN/CLOSE key is
www
pressed?
NO
.
Motor defective.
Control IC (IC400) defective.
Microcomputer defective.
http://www.xiaoyu163.com
DESCRIPTION
Data cannot be read.
Check by using
YES
another disc.
NO
TRACKING servo
defective.
Outermost
FEED servo
(on mirror
surface)
defective.
Within disc range
................ Poor tray loading
operation.
SW401 detection poor.
YES
Microcomputer defective.
x
ao
u163
y
i
http://www.xiaoyu163.com
CDC-585/CDC-506/CDC-685/CDC-906
2 9
8
Q Q
3
6 7
1 3
1 5
X6 ........................
Error code
Does tray rotate in
TEST mode?
YES
Tray sensor defective.
Microcomputer defective.
X7 ..........
Error code
Is forced feed
operation available
in TEST
mode?
NO
FEED servo defective.
co
Microcomputer defective.
.
9 4
2 8
* Meaning of each state ("X") :
(X = 0)PLAY
(X = 2)SCAN
(X = 3)PAUSE
(X = 4)PEAK SEARCH
(X = 5)SEARCH
(X = 6)DISC SCAN
(X = 7)START
(X = 8)STOP
(X = 9)DISC SEARCH
(X = –)EJECT
(X = C) ........... NO DISC
0 5
8
2 9
9 4
2 8
Poor table rotation.
Motor defective.
NO
Drive circuit defective.
DISC
Microcomputer defective.
SKIP
FEED operation defective.
(Limit switch fails)
Feed limit switch
YES
defective.
Microcomputer
Y ...Outward
defective.
T ...Inward
m
9 9
9 9