13.12.2000 / Page 2
Doc. No: 4812 718 15955

Technical data

Dimension
Height
Width
Depth
Weight
Wooden door (for 22 mm thickness)
Thickness min..
Thickness max.
Width min.
Width max.
Height min.
Height max.
Weight min.
Weight max.
Max. stick out over lower
edge of appliance door
Height of plinth min.
Electronic boards
Service boards
Serial boards
UB
CB
Dataset
Succession of programs
Programs
Succession
Alarms
Refill rinse aid
Options
Zone washing
Program information
Start indicator
6ADG 952/3 WHM
8542 952 53410
82.0-87 .0 cm
59.7
cm
55.5
cm
52.7
kg
16
mm
20
mm
592
mm
595
mm
620
mm
718
mm
2.5
kg
6.5
kg
92
mm
93
mm
see spare part list
4619 720 80502
413212
413202
see program diagram
1a-4b-6b-6d-7a
Whirlpool Europe
Customer Service
Volume (normal program)
Water
Regeneration
Back rinse 3x
Prewash
Prewash/Zone washing
Main wash
Main wash/Zone washing 3.5 l
Intermediate rinse 1
Intermediate rinse 1/
Zone washing
Intermediate rinse 2
Intermediate rinse 2/
Zone washing
Clear rinse
Clear rinse/Zone washing 3.5 l
Safety / overflow
Measuring the level
Remove the coarse sieve, put in a measuring
meter into the sump, measure the hight of the
water level.
Detergent max.
Pre-wash
Main-wash
Rinse aid
6 Dosage steps
Water pressure
Inlet pressure
Spray pump pressure
Rotations
Spray pump motor
Drain pump motor
Spray arm lower
Spray arm upper
Ceiling rotor
S E R V I C E
Volume
Level
0.3 l
15 mm
1.0 l
68 mm
4.8 l
122 mm
4.0 l
120 mm
4.5 l
121 mm
117 mm
4.0 l
120 mm
3.5 l
117 mm
4.0 l
120 mm
3.5 l
117 mm
4.0 l
120 mm
117 mm
8.5 l
141 mm
3
10
cm
3
45
cm
3
125
cm
1 - 6
ml
0.3-10
bar
0.4
bar
2800
RPM
3000
RPM
20 - 40
RPM
25 - 35
RPM
45 - 65
RPM

Hide quick links: