Smeg P23LIN Installation & User's Instructions
Smeg P23LIN Installation & User's Instructions

Smeg P23LIN Installation & User's Instructions

Wall mounted high efficiency gas fire

Advertisement

INSTALLATION & USER INSTRUCTIONS
WALL MOUNTED HIGH EFFICIENCY GAS FIRE
SMEG S.p.A. 42016
Guastalla (RE)
ITALY
MODELS COVERED BY THESE INSTRUCTIONS
P23 LINEAR
P23 CLASSIC
L23 LINEAR
L23 CLASSIC
L30 FAB
P23 Linear
L23 Linear
Please note : Except where otherwise stated, all rights,
including copyright in the text, images and layout of this
booklet is owned by Smeg S.p.A. You are not permitted to
copy or adapt any of the content without the prior written
permission of Smeg S.p.A.
This product is tested and approved to EN14829 : 2007.
All instructions must be handed to the user for
L30 Fab
GB-IE-1
-
P23LIN
-
P23CL
-
L23LIN
-
L23CL
-
L30FAB
safekeeping.
©
GB IE
P23 Classic
L23 Classic
2008 Smeg S.p.A.

Advertisement

Table of Contents
loading

Summary of Contents for Smeg P23LIN

  • Page 1 Please note : Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet is owned by Smeg S.p.A. You are not permitted to copy or adapt any of the content without the prior written permission of Smeg S.p.A.
  • Page 2: Table Of Contents

    It Does Not Give Full Protection For Young Children Or The Infirm. Where young children, pets, the elderly or infirm are concerned, a suitable fireguard should be used. • Consult ALL instructions before installation and use of this appliance. This appliance is free from any asbestos material. GB-IE-2 2008 Smeg S.p.A. ©...
  • Page 3: Appliance Data

    This is to allow adequate circulation of air and ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces must not be separated by a door. Note : To calculate a room size in cubic metres (m ) divide the room volume in cubic feet (ft ) by 35.3. GB-IE-3 2008 Smeg S.p.A. ©...
  • Page 4: Site Requirements

    ODS system. The appliance shall not be installed within 1 metre of any existing air vent, and any new air vent shall not be installed within 1 metre of the appliance. Note : With the appliance installed in the minimum size room and with the ventilation specified, the concentration of NO2 in the room is less than 300ppb. GB-IE-4 2008 Smeg S.p.A. ©...
  • Page 5: Unpacking The Appliance

    The wall where the appliance is both the wall and any wall fixings used are sufficient. to be installed must be capable Smeg S.p.A. assumes absolutely no responsibility for injuries and damages that may of long-term support of the total load of the appliance. Measures occur due to improper installation or handling.
  • Page 6: Checking The Burner & Spark Gap

    Ensure the inlet adaptor/connection is fully tightened. Turn on and test the gas supply up to the fire for any leaks, in accordance with local Codes and/or Regulations. GB-IE-6 2008 Smeg S.p.A. ©...
  • Page 7: Operating The Appliance

    In the event that the burner pressure is not in accordance with the figures stated in the data section of these instructions, the appliance must not be commissioned, and the manufacturer should be contacted for guidance. GB-IE-7 2008 Smeg S.p.A. ©...
  • Page 8: Fitting The Decorative Frame

    12. Refit the decorative facia/frame assembly as detailed in section 8.3. 13. Check the purpose provided ventilation is un-obstructed. 14. Light the fire and test setting pressures. 15. Check safe operation of the appliance. For specific servicing instructions, see relevant sections. GB-IE-8 2008 Smeg S.p.A. ©...
  • Page 9: Servicing The Burner Unit

    MUST not be done. Replacements must be original manufacturers parts. Re- assembly is the reverse of removal. Ensure setting pressures are as stated in Section 2; Appliance Data. GB-IE-9 2008 Smeg S.p.A. ©...
  • Page 10: Catalysts

    It is important to note that the appliance can never be expected to be 100% smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the fire is in operation. GB-IE-10 2008 Smeg S.p.A. ©...
  • Page 11: Troubleshooting Guide

    THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. Fire smells when first lit or in use Newness smell from brand new appliance. Leakage occurring. Carry out leakage test and rectify any problems. Combustible materials used in incorrect positions. GB-IE-11 2008 Smeg S.p.A. ©...
  • Page 12 The appliance must not be positioned vertically within 60mm (2.4”) of a solid floor (i.e. wood or stone) or hearth. This dimen- sion is measured vertically to the bottom of the appliance firebox. GB-IE-1 2008 Smeg S.p.A. ©...
  • Page 13 This appliance is intended as a secondary source of heat only and should not be used in a room without some form of back- ground heating present. If the appliance is used in a room as the sole source of heat, then condensation may occur on colder surfaces within the room. GB-IE-2 2008 Smeg S.p.A. ©...
  • Page 14 PAINTED AREAS - These can be cleaned using a dry cloth. FINISHED METAL AREAS - These can either be cleaned using a proprietory metal cleaner. Test on a small hidden part before cleaning. Always clean in the direction of the grain. GB-IE-3 2008 Smeg S.p.A. ©...
  • Page 15: Service History

    Contact details of Engineer Serviced by : As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications without prior notice. GB-IE-4 2008 Smeg S.p.A. ©...