Advertisement

MODEL
JT-MC206GS-W-E
Unit color
-W
(White)
INSTRUCTION MANUAL
■ Read the manual thoroughly before using the unit to ensure it is used safely and correctly.
After reading the manual, store it in an easily accessible location for future reference.
This unit is intended for the purpose of drying hands and is not covered by a warranty if used for any other purpose.
It has no sterilizing or disinfecting functions.
INDEX
Hand dryer
You should not attempt to install the unit yourself,
as this may affect the safety and functionality of the unit.
Location of Model Name display
Location of power supply voltage display
2
3
4
4
4
5
5
5
6
6
7
7
8
8
9
10
11
12
− 1 −
1209875HF0401
Single-phase 220 - 240V AC
For User
GB

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi JT-MC206GS-W-E

  • Page 1: Table Of Contents

    1209875HF0401 Hand dryer MODEL JT-MC206GS-W-E Location of Model Name display Unit color (White) Location of power supply voltage display Single-phase 220 – 240V AC For User INSTRUCTION MANUAL ■ Read the manual thoroughly before using the unit to ensure it is used safely and correctly.
  • Page 2: Safety Precautions

    Safety Precautions The dangers arising from improper handling and the extents of the dangers are classifi ed and explained as shown below. The following may lead to death or Warning serious personal injury if handled incorrectly. Do not install in locations where they may be Do not modify or disassemble the unit.
  • Page 3: Names Of Parts

    Names of Parts ※ Shaded areas in the fi gure indicate antibacterial material (excluding outlet nozzle areas). Inside the front cover (Refer to "How to open/close the front cover" on page 4) Power light Front cover Setting switches Power switch Air fi...
  • Page 4: How To Use The Unit

    How to use the unit ■ How to open/close the front cover How to open the front cover Pull the tab for opening the Hold the handle are on the Open. front cover. right hand side of the main unit. Main Main unit...
  • Page 5: Turning The Power On

    ■ Turning the power on Open the front cover. Turn the power switch "ON". Refer to "How to open/close the front cover" on The power light (blue) turns on. page 4. Power switch Pull the tab. Power "ON" Power "OFF" O F F O F F Open...
  • Page 6: Turning The Heater On

    ■ Turning the heater on Open the front cover. Open Refer to "How to open/close the front cover" on page 4. Front cover Press the air speed switch or the heater switch and let the settings light turn on. Turn the heater switch "ON". ※...
  • Page 7: Maintenance

    Maintenance Warning Caution Always turn off the power switch during Wear gloves during maintenance work. maintenance work. Not doing so may result in injuries. Failure to do so may result in an electric shock. Do not allow water to get on the unit. This may cause electric shocks or malfunctions.
  • Page 8: ① Turning The Power Off Before Maintenance

    Maintenance - Continuation Turning the power off before maintenance Pull the tab and open the front Open the front cover and turn the power switch "OFF". cover. Power switch Front cover Main unit Power "OFF" O F F Pull Front cover Open Cleaning the unit exterior and hand drying area Power switch...
  • Page 9: ③ Cleaning The Air Filter

    Maintenance - Continuation Cleaning the air fi lter Around once a week If the air fi lter is not cleaned, the working life of the motor and heater may be shortened, the drying Caution performance may be decreased due to insuffi cient air volume and air speed and bacteria can grow in the fi...
  • Page 10: ④ Cleaning The Drain Tank

    Maintenance - Continuation Cleaning the drain tank Before it fi lls up (at least once a week) Empty the drain water at least once a week before the drain water exceeds the full line. If the drain water is left inside, it can cause foul odors or the water can spill onto the fl oor and tarnish it. Power switch Pull the tab, open the front cover and turn the Front cover...
  • Page 11: Trouble Shooting

    Trouble shooting Implement the inspections and procedures below in the following cases. In such cases Inspections Procedures Are any lights in the display on? Turn the ground fault circuit interrupter on. Has a blackout occurred? Turn the power switch "ON". Are you putting your hands in all the way? Place your hands all the way inside the hand drying area.
  • Page 12: Specifi Cations

    When keeping the noise level down during operation 54dB ※ Drying times are based on Mitsubishi measurements. (50mg of water per hand) Working life of the motor/heater The working life of the motor and heater is 7 years when used 120 times per day with the air speed set at "High".
  • Page 13 2006/66/EC Article 20 Information for end-users and Annex II. Français English Votre produit Mitsubishi Electric est conçu et fabriqué avec des matériels et des composants de qualité supérieure qui peuvent être Your MITSUBISHI ELECTRIC product is designed and recyclés et/ou réutilisés.
  • Page 14 Var snäll och hjälp oss att bevara miljön vi lever i! Nederlands Dansk Mitsubishi Electric producten zijn ontwikkeld en gefabriceerd uit Dit produkt fra MITSUBISHI ELECTRIC er designet og fremstillet eerste kwaliteit materialen. De onderdelen kunnen worden med kvalitetsmaterialer og komponenter, der kan genindvindes gerecycled en/of worden hergebruikt.
  • Page 15 Mitsubishi Electric Corporation registration number: ○○○○○ Manufacturer HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN AUTHORIZED REPRESENTATIVE IN EU: MITSUBISHI ELECTRIC EUROPE B.V.HARMAN HOUSE, 1GEORGE STREET, UXBRIDGE, MIDDLES Motor Power Input (kW) 0.02 Flow Rate (m Pressure (Pa)